background image

Warnings

 

• 

Avoid having water near any electric connection. Make sure 
the power plug is dry before plugging it into any power outlet.

 

• 

Please do not use tap water in humidifier units.  Tap water will 
cause damage to humidifiers, humidors and cigars.  

 

• 

Make sure there is gel in the tank.

  

If you would like to use 

without gel, don

t use distilled water because the water sensor 

will not detect water since distilled water is too pure, instead 
use carbonated filtered drinking water.

 

• 

If the Flat Cable needs adjusting, follow the provided            
instructions to avoid damaging it. 

 

• 

If lime build up is seen on the two water sensor poles, clean 
with de

-

lime or vinegar.

  

Make sure no liquid gets into the   

humidifier.

 

Recalibrating the Hygrometer

 

Each Le Veil humidifier is equipped with a capacitive humidity sensor, 
the same used in commercial laboratories. Most digital hygrometers 
available are equipped with resistive sensors which can have a RH     
variance of +/

-

 10%. Please make sure the hygrometer used to match 

humidity has a capacitive humidity sensor. 

 

 

To calibrate the iCigar Pro humidifier, hold the 
'MODE' button (keep holding it) and    before the 
numbers flash in the bottom right corner, imme-
diately adjust the meter with the 'UP' and 'Down' 
buttons. The numbers on the upper left side of the humidifier will     
increase or decrease depending on what you need. Use this function to 
match the humidifier to the other hygrometer that you are trying to 
match it to. 

 

Factory Pre

-

set

 

70%

 

Humidifier Accuracy

 

+/

-

 1%

 

Humidity Range 

 

40%

-

90%

 

Wall Outlet Power

 

100

-

240V AC,  12V DC

 

Size 

 

9”

Lx4 3/4W

x4 

1/2”

H

 

Engineered in USA

 

Manufactured in China

 

Patent rights issued 

 

and /or pending

 

www.leveil.us

 

Summary of Contents for iCigar Pro DCH-67

Page 1: ...CB FT humidors Up to 110 CB FT w sub tank not included Two Powerful and quiet fans Back lit liquid crystal display 1 Humidity sensor 2 Flat power cable 3 Power port for support slave unit 4 Air out ventilation 5 Air in ventilation 6 Water sensor 7 Power light 8 12V power port 9 Control buttons 10 Reset memory button 11 Support Leg 12 MP XS AP ports are for future features 13 Bluetooth Adapter Port...

Page 2: ... Controller unit and gently ex tend the cable lock out to plug in the Flat Cable head The cable should have the blue side facing up and be positioned in the cen ter B Push the cable lock in to secure the Flat Cable head C Replace the back cover D Open the back cover on the fan enclosure and pull the cable lock out to plug in the Flat Cable head The cable should have the blue side facing up and be ...

Page 3: ...n for 3 seconds until the RH setting numbers flash in the bottom right of the screen 2 Release the MODE button and use the UP and DOWN buttons to raise or lower the target humidity RH setting The humidifier fan will turn on and off depending on what the RH setting is set to Quickly press MODE to switch from C or F Press UP or DOWN to display the Max Min humidity When the water level becomes low th...

Page 4: ...Each Le Veil humidifier is equipped with a capacitive humidity sensor the same used in commercial laboratories Most digital hygrometers available are equipped with resistive sensors which can have a RH variance of 10 Please make sure the hygrometer used to match humidity has a capacitive humidity sensor To calibrate the iCigar Pro humidifier hold the MODE button keep holding it and before the numb...

Reviews: