Service & Repair 99
4.
Shift the carrier panel lever outward to apply hydraulic
pressure to the case end of the carrier
cylinders. Hold the lever and observe the fluid flow from the open port on the rod end.
The flow of hydraulic fluid should be no more than 2 fluid ounces per minute. A flow greater than
2 ounces indicates an excessive piston seal leak. If the cylinder does not leak excessively, continue
test.
5.
If the cylinder does not leak, reconnect hydraulic
lines to the rod end of cylinder and tighten to
110
ft-
lbs. Repeat steps 3-5 for other cylinder.
6.
Shift the carrier panel lever inward to retract the carrier panel cylinder.
OPERATIONAL STATUS
Truck Running
PTO Engaged
Speed Up On
Transmission Neutral
OPERATIONAL STATUS
Truck Off
PTO Disengaged
OPERATIONAL STATUS
Truck Running
PTO Engaged
Speed Up On
Transmission Neutral
CARRIER
PANEL
LEVER
OBSERVE
FLUID FLOW