76 Troubleshooting
PACKER PANEL VALVE SECTION WILL NOT SHIFT
Possible cause
Remedy
Packer panel cylinder leaking
Perform test for leaking cylinder. See Chapter 8
Service and Repair
.
Packer panel valve section shift pressure
too high
Perform pressure check as described in
Linkage binding or restrictive
Inspect and free linkage as necessary.
CARRIER PANEL VALVE SECTION WILL NOT SHIFT TO NEUTRAL
Possible cause
Remedy
Carrier panel cylinder leaking
Perform test for leaking cylinder. See Chapter 8
Service and Repair
.
Carrier panel valve section shift pressure
too high
Perform pressure check as described in
Packer and Carrier Panel Shift (Knockout) Pressures
Linkage binding or restrictive
Inspect and free linkage as necessary.
PACKER/CARRIER PANELS DO NOT DELIVER FULL FORCE TO PACK LOAD INTO BODY
Possible cause
Remedy
Hydraulic pressure incorrect
Perform pressure check as described in
Hydraulic fluid in tank is low
Add fluid to correct level (see
Tank strainer screen is dirty (this
condition will starve pump and cause
noise in the system)
Service system as described in
Wrong type of hydraulic fluid in system Drain and refill with correct type of hydraulic fluid
Flushing Hydraulic System / Cleaning Hydraulic
Main relief section of Front Control
Valve opens too soon
Adjust main relief setting on Front Control Valve
(see
Summary of Contents for 2R-III
Page 1: ...2R III MAINTENANCE MANUAL...
Page 2: ......
Page 3: ...2R III MAINTENANCE MANUAL...
Page 5: ......
Page 6: ......
Page 20: ...10 Introduction...
Page 42: ...32 Safety...
Page 58: ...48 Preventive Maintenance Figure 5 1 Hydraulic tank w return filter 1 2 3 4 5 6 7 8...
Page 66: ...56 Preventive Maintenance...
Page 102: ...92 Troubleshooting...