78 Troubleshooting
PUSHOUT PANEL WILL NOT SLIDE FORWARD AUTOMATICALLY
Possible cause
Remedy
Resistance setting too high
Reduce resistance setting
Packer/carrier panels not applying full
force to move pushout panel forward
Check pressures.
Check pump.
CARRIER AND PACKER PANELS STOP SHORT OF HOME POSITION AFTER EACH CYCLE
Possible cause
Remedy
Unit full
Empty unit.
Resistance setting too high
Reduce resistance setting
Packer/carrier panels do not deliver full
force
See Chapter 7
Troubleshooting
.
PACKER PANEL DRIFTS OPEN WHILE PACKING LOAD INTO BODY
Possible cause
Remedy
Packer panel cylinder seal leaking
Perform test for leaking cylinder. See Chapter 8
Service and Repair
.
Packer panel valve section shift pressure
too low
Perform pressure test as described in
CYCLE TIME TOO SLOW
Possible cause
Remedy
Engine RPM too low
Set engine RPM to achieve 23 to 26-second cycle
time (
must be done by an authorized dealer
).
Hydraulic fluid level too low
Hydraulic fluid filter needs servicing
Hydraulic tank breather dirty