26
6
FAILURE
Maintenance level:
Level 1:
Can be carried out by users.
Level 2:
only carried out by a qualified mechanic.
Level 3:
only carried out by the manufacturer.
Symptoms
Possible cause
Solutions
Level
Indicator
[14]
on red
Lack of fuel
Fill the fuel tank
1
Indicator
[13]
on red
Battery low
Recharge the battery
1
The engine will not start
The trailer brake is not on
Put the trailer brake on
1
Defective fuel pump
Change the fuel pump
2
No more fuel
Fill the fuel tank
1
The battery is low
Recharge the battery
1
The engine temperature is rising
and reaches 130°C
The surrounding
temperature is too high
Reduce the engine
speed and check the
temperature drop
1
Dirty radiator
Clean the radiator
2
The engine cuts off
No more fuel
Fill the fuel tank
1
The fuel filter is dirty
Change the fuel filter
2
Insufficient air supply
Clean or change the air
filter
2
Dirty spark plugs
Replace the spark plugs
2
The engine will not reach its
maximum speed or operates
erratically
Dirty spark plugs
Replace the spark plugs
2
Dirty air filter
Clean or change the air
filters
2
Rods out of line
Adjust the engine speed
2
The starter is not operational
Engine equipment fuse
blown
Change the fuse
1
The engine misfires at top speed
The engine speed is
above 7000rpm
Adjust the engine speed
2
The starter works but the engine
does not start
ECU Fuse blown
Change the fuse
1
No power supply when the
battery cut-off is on
"1"
Control panel fuse blown
Change the fuse
1
The battery does not charge when
the charger is used
Charger protection fuse
blown
Change the fuse
1