background image

 
 

 

 

 

  Do not try to start the Aeros with the pressure regulator in position 

0 or 3

 

  Do not smoke during these operations 

 

  We  recommend  the  use  of  work  site  type  13  kg  or  35  kg  propane  gas  bottles  from 

Antargaz

. To find out where to purchase them

http://www.Antargaz.com

 

 

  The Aeros appliance only operates using propane gas in its gaseous state. Always supply it 

using vertical bottles; do not lay the bottles on their  sides as this would cause the Aeros to 
operate with the gas in liquid state and would permanently damage the entire gas circuit. 

 

    Any type of extinguishing agent can be used with the 

AEROS2

 

  Be careful when using foam: it traps the has which risks igniting further away when it is no 

longer in the tank.  

 

  It  is  possible  that  trainees  manage  to  blow  out  the  flames,  especially  when  using  a  Co² 

extinguisher.  Release the  remote  control button.  The  trainee  will  have  the  impression  that 
they put the fire out. 

 

  Do not keep the remote control button pressed down if no flames appear, to prevent the 

spread of non ignited gas and its unplanned ignition outside the flame generator tank.  

 

  After an intervention, wait for a few seconds and reset the pressure regulator to position               

1 or 2

 before reigniting the fire, so that the tank is no longer saturated with gas. 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for AEROS 2

Page 1: ...AEROS 2...

Page 2: ...Product reference V90 00 036 AEROS2...

Page 3: ...2 2 SAFETY INSTRUCTIONS 3 3 GENERAL SPECIFICATIONS 4 4 OPTIONS 6 6 MAINTENANCE OPERATIONS 10 7 SPARE PARTS LIST 11 8 MALFUNCTIONS 13 9 WARRANTY 14...

Page 4: ...tructions before using the equipment Check the condition of the gooseneck regularly The unit only works with Propane gas It is forbidden to feed your flame generator with propane in liquid form especi...

Page 5: ...no sand or gravel enters through the joints of the pipe or the apparatus This could damage the electro valve The battery can be discharged down to a minimum of 10v Beyond this it will not be possible...

Page 6: ...gas cylinder without flowrate limiter bottle or two 13 Kg Propane gas domestic type with a penalty ref V90 80 053 limiter kit Adjustable gas Regulator Lyre 6m manually disconnectable Lyre 6m quickly...

Page 7: ...6 4 OPTIONS To position the Accessory Adapter Gas supply pipe kit for all flames generators In order to use 2 Propane gas cylinders Ref V90 80 053...

Page 8: ...e Recharge the battery for at least 12 hours Side holes Place the fire generator tank on a flat surface to make sure the water level is even in all areas Place it so that the remote control cable and...

Page 9: ...on valve to 0 if there is a problem If the operator needs to move away from the gas bottle they must assign a person to be ready to cut the gas supply in the event of a problem The remote control is s...

Page 10: ...as circuit Any type of extinguishing agent can be used with the AEROS2 Be careful when using foam it traps the has which risks igniting further away when it is no longer in the tank It is possible tha...

Page 11: ...rt of the tank is very hot after use Before handling the tank hose it down with water to cool it wear gloves Wash the tank abundantly with water to remove any powder or other extinguishing agent resid...

Page 12: ...HOUT maintenance formation Picture Lev R f D signation 1 2001238 SPARK PLUG 1 2001707 REMOTE CONTROL UNIT 1 2001071 BATTERY 1 2001132 ELECTRO VALVE 1 2001070 HIGH VOLTAGE UNIT 1 2001054 BLACK BATTERY...

Page 13: ...2 2001072 FEMALE CONNECTOR 2 2001073 MALE CONNECTOR 2 2001708 FEMALE COUPLING 8 2 2001247 BODY OF REMOTE CONTROL 2 2001250 PE SKINTOP 2 2001249 ANTIVANDAL BUTTON Maintenance Level 2 Spare parts suppl...

Page 14: ...k is produced you can hear the continuous tick tick of the firing system Is the gas bottle open Open the gas bottle Check the position of the pressure regulator knob If it is on 0 turn it to position...

Page 15: ...f LEADER the claimant must return the equipment in the shortest possible time after discovery of the defect to the following address LEADER SAS Maintenance Department ZI des Hautes Vall es Chemin No 3...

Page 16: ...15 Code Notice AEROS2 00 ZN4 43 EN 0...

Reviews: