15
6.4 Gasoline failure
After a gasoline failure, you must re-prime the fuel pump by using the following procedure:
Activate the starter. If the engine does not start within 5 seconds, release the key and wait at least
10 seconds before activating the starter again. This is due to priming the fuel pump.
When the engine starts, release the key; it should return to the
ON
position.
6.5 Recharging the battery
The
EASY2000
is fitted with a socket for recharging the battery.
In order to ensure a sufficient charge level, it is recommended to recharge the battery once a month.
A charger is provided with the fan. The charger can be maintained connected without any time limit
6.6 Misting
The misting system must be supplied with water after the engine is started. On the versions with lift,
the fan will need to be raised before the water is supplied. The connection is delivered in male thread
1"1/2BSP.
Misting water connection
Battery charger socket