background image

                                                                                                                                                                                                                                   

MT240.0ZN.3.34.US.1

 

 

ATTENTION:

 Dot not attempts to start the

 MT240

 ventilator if you notice any kind of 

anomaly. Contact  

Leader SA

 immediately.

 

  

The following checks must be carried out before first starting the fan: 

 

Make a visual check of the 

MT240 

and its accessories to make sure that no damage 

occurred during transport

- Check that the manual for the HONDA is contained in the pack. 
 
With the engine off, pull the recoil starter. If there is any unusual noise, or if the turbine 
gets stuck, stop the engine and contact 

Leader SA 

immediately. 

 

Read the instruction manual for the engine before filling up with oil or petrol. 

 

Use the fuel and lubricant recommended in the instruction manual for the engine: fresh, 
unleaded petrol with an octane rating of at least 85. 
 
Fill the engine’s oil sump with a type of oil recommended in the instruction manual. 
 

MT240 : engine HONDA: oil capacity: 0.5 litre (20W50)

 

 
The limits for oil use are shown in the HONDA engine manual. 

 

Make sure that everyone responsible for or using this equipment is fully aware of the 
safety and operating precautions pertaining to rotating machinery. 

 

NB : 

By its nature, a petrol engine creates vibrations. It is normal for the fan to vibrate when 

in use, particularly at medium power. To ensure better stability for the 

MT240 

fan, particularly 

on an uneven surface, put the accelerator up to maximum power. This will reduce the 
vibrations and improve the equipment’s stability. 

 

It is possible that there will be some extraneous vibration 

during the engine’s running-in 

period. These will disappear after several h

ours’ use. 

 

  INSTRUCTIONS FOR START-UP :

 

 

START-UP OPERATIONS : 

The way the 

MT

240

 

fan is started depends on the terrain on which it is being used. 

 
 

1/ 

Check that the fuel tank is full. 

2/ 

Check that there is no fuel leakage. 

3/ 

Place the 

MT

240

 

fan on a flat surface where there are no slippery products and which is 

clear of debris. Make sure there is no obstacle between the fan and the opening for air 
entry. 

4/ 

Start the fan after making sure that it is in a stable position, and adjust the accelerator so 

as to obtain the desired airflow. (For more information, see the engine manufacturer’s 
manual). 

5/ 

During blowing operations, regularly check that no obstacle is preventing the airflow 

from penetrating the interior of the building, or blocking the fan’s suction grill

 

 

 

Easy Pow’air MT240 : GENERAL FEATURES 

    

Manufacturer’s reference  

I60.10.060  

& I60.10.061

 

    Manufacturer LEADER 

S.A.S

, Octeville sur mer - FRANCE

  

Construction : 

• 

 Chassis in ø 30mm steel tube 

– epoxy coating  

• 

 Engine Honda GX160 type 

– 4-stroke – 6.5 HP at 3600 rpm 

(SAEJ1349 : 5.5CV)

 

• 

Guard of the turbine in double polyethylene skin

 

• 

Turbine made of composite resin - ø 420 mm 

– aluminium axle 

• 

Operating autonomy 

_ 2h 00 

at full speed 

• 

Standard equipment : engine stops automatically in the event of shortage of oil or if the 

fan is accidentally knocked over. 

• 

Noise level around 92.1 dB(A) at 3 m. 

• 

Retractable handle, two 200mm diameter wheels. 

• 

Angle of tilt adjustable (from 10° to 20°). 

• 

Airflow: 49681 m

3

/h

 

 

 

 
 
Guarantee: 
 

2 years, parts and labour, for the engine, see manufacturer’s documentation 

This equipment is designed and manufactured in FRANCE, in compliance with CE 
directives. 
 
This equipment should be used only by firefighting professionals

 

 
 

 

                   ADJUSTING THE TILT:

 

Use between 2 and 6 metres from the opening

 

 
  1)

  Lift the carrying handle, the fan is 

automatically tilted to an angle of 10° 
(operating angle recommended for 90% of 
incidents). 

 

2)

 To close the carrying handle, 

unlock it using the index pin (ref. A). 

   ADJUSTING THE TILT: LANDING, ENTRY WITH STEPS, 

WINDOW

 

Use between 4 and 6 metres from the opening

 

 

1) 

To adjust the tilt between 10° 

and 20°, unlock the tilt adjustment 
lever by moving it a quarter turn. 
 

2) 

Tilt the fan manually so as to 

centre the jet on the opening. 
 

 

3). 

Lock the lever while holding the 

fan in place so as not to alter the tilt. 
 

 

Must be deployed  
Before start the engine 

 

MAX 

  

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

To tip  

20° 

10° 

To

 

unlock

 

To lock 

Weight : 43 Kg 
+/- 0.5 Kg 

US 