6. HDR DISPLAY (SER07)
92
6. HDR DISPLAY (SER07)
You can measure HDR signals by installing SER07. HDR signal measurement supports all
formats except for SD and XYZ.
To measure HDR signals, on the SYS
→
F•1
SIGNAL IN OUT →
HDR tab, set HDR MODE to ON.
If necessary, set the STANDARD, HDR->SDR HIGH UPPER LIMIT, SYSTEM GAMMA and
REFERENCE LEVEL parameters. For details, see the LV 5490 instruction manual.
When HDR measurement is turned on, the following occurs.
When 5-bar display, gamut error display on the picture, gamut error display on the status,
composite gamut error display, luminance level error, or chrominance level error turns on, the
SDR conversion format selection is reduced to DISABLE only. If the SDR conversion format is
set to a value other than DISABLE, it is changed to DISABLE.
Figure 6-1 HDR tab
2. On the HDR tab, set HDR MODE to ON.
If necessary, set the STANDARD and HDR->SDR HIGH UPPER LIMIT parameters. For
details, see the LV 5490 instruction manual.
Figure 6-2 HDR tab