9. LOUDNESS DISPLAY
53
9.2
Configuring the Loudness Display Settings
To configure the loudness display settings, use LOUDNESS on the front panel,
F•2
LOUDNESS SETUP on the mode menu and the METER 2 tab in the system settings. This
section explains LOUDNESS on the front panel and F•2 METER SETUP. For details on the
METER 2 tab, see section 5.7,
“Configuring the Loudness Settings.”
Figure 9-5 Front panel
●
START/PAUSE
When Trigger is set to OFF on the METER 2 tab in the system settings, press this key to
start and pause loudness measurement. “MEAS” is displayed in the upper right of the
screen when measurement is in progress. This key is valid regardless of the display mode.
●
USB STORE
Press this key to store a loudness log to a USB memory device in CSV and text formats.
This key is valid regardless of the display mode.
Loudness logs are stored in the following location.
USB memory device
└
LV5838_USER (or LV5837_USER)
└
LOUD
├
yyyymmddhhmmss.csv .... Settings on the METER 2 tab, loudness values, check results
└
yyyymmddhhmmss.txt...... Current time, time codes, and loudness values
●
CLEAR
When Trigger is set to OFF or Timecode on the METER 2 tab in the system settings, hold
this key down to clear the integrated loudness, chart display, and peak level display. This
key is valid regardless of the display mode.