Safety Precautions
Safety must always be your primary concern during the assembly, installation and operation of your
LE-600 turbine
. Always be aware of the risks involved with mechanical and electrical installation
work. If in doubt about any issue regarding your turbine, please seek further assistance before
proceeding. Installation of the LE-600 turbine should only be undertaken by suitably competent and
qualified personnel.
Mechanical Safety Hazards
•
The main rotor is the most obvious and serious mechanical safety risk. When the turbine is
operating at its rated performance, the blades will be very difficult to see due to the speed
of rotation. Never approach the turbine whilst it is operating. Always shut down the
turbine by activating the stop switch.
Ensure that the turbine is installed in a suitable
position where nobody can approach or interfere with the path of the rotor blades.
•
Working with tools of any kind can be dangerous. Your
LE-600 turbine
requires some basic
mechanical assembly with rudimentary hand tools. If you are in any doubt about how to
use these tools correctly, please seek advice from a suitably experienced person.
•
Your
LE-600 turbine
will inevitably be installed upon a tower or other support mount. This
may mean working at height. Always ensure that all personnel in the immediate vicinity
are aware of any lifting / hoisting operations that will be occurring. Check there are no
loose components or tools likely to fall and cause injury during the lifting operation. Where
possible, all assembly work should be completed at ground level. In the case of roof mount
brackets, a suitable fitter should carry out the installation with the appropriate equipment
for working at height.
•
Ensure that the batteries are disconnected during the installation procedure.
•
Twist the turbine output cables together (to create a short circuit) during the mechanical
installation process. This will prevent the turbine from ‘spinning
up’ during the installation.
•
Never install the turbine upside down or in any orientation other than that depicted on the
installation instructions.
•
Install your turbine during a calm day.
•
When performing routine inspection or maintenance, always stop the turbine by activating
the stop switch.
Electrical Safety Hazards
•
The
LE-600
generates 3-Phase AC voltage from the turbine head and rectified DC voltage
from the rectifier box. Even at low voltages there are inherent risks. Caution should always
be used when connecting
LE-600
to the electrical system.
•
Ensure that you have followed the cable-sizing chart to ensure that the correct size of
transmission cable has been selected. If a cable of insufficient cross-sectional area is used,
heat may build up in the cables causing a potential fire hazard. A properly sized fuse or
circuit breaker should be used in the cables connected to the battery. This will stop the risk
of short circuit currents. Using cables of insufficient cross-sectional area may also reduce
the power transmission efficiency of the turbine.
•
Batteries systems can deliver a serious amount of current. A short circuit in the battery
circuit can lead to hundreds of amps flowing through the battery cables. This will cause a
heat build-up and ultimately an electrical fire. Batteries can explode when shorted. Always
use insulated electrical tools when working on the battery’s electrical connections.
•
Batteries are very heavy. Do not attempt to move batteries by yourself. Always use manual
handling tools and an assistant.
•
Always keep lead-acid batteries the correct way up. Do not allow the acidic electrolyte to
spill or come into contact with your skin or face. Always follow the manufacturer’s safety
instructions when handling lead-acid batteries.
•
Never run the LE-600 'off-load' with the output cables not connected to anything.
Please use common sense when installing and operating your turbine!
Summary of Contents for LE-600
Page 28: ...Tel 44 0 1981 241668 www leadingedgepower com Page 28 of 48 Rev Q...
Page 29: ...Tel 44 0 1981 241668 www leadingedgepower com Page 29 of 48 Rev Q...
Page 30: ...Tel 44 0 1981 241668 www leadingedgepower com Page 30 of 48 Rev Q...
Page 31: ...Tel 44 0 1981 241668 www leadingedgepower com Page 31 of 48 Rev Q...
Page 32: ...Tel 44 0 1981 241668 www leadingedgepower com Page 32 of 48 Rev Q...
Page 33: ...Tel 44 0 1981 241668 www leadingedgepower com Page 33 of 48 Rev Q...
Page 34: ...Tel 44 0 1981 241668 www leadingedgepower com Page 34 of 48 Rev Q...
Page 35: ...Tel 44 0 1981 241668 www leadingedgepower com Page 35 of 48 Rev Q...
Page 36: ...Tel 44 0 1981 241668 www leadingedgepower com Page 36 of 48 Rev Q...
Page 37: ...Tel 44 0 1981 241668 www leadingedgepower com Page 37 of 48 Rev Q...
Page 38: ...Tel 44 0 1981 241668 www leadingedgepower com Page 38 of 48 Rev Q...
Page 39: ...Tel 44 0 1981 241668 www leadingedgepower com Page 39 of 48 Rev Q...
Page 40: ...Tel 44 0 1981 241668 www leadingedgepower com Page 40 of 48 Rev Q...
Page 45: ...Tel 44 0 1981 241668 www leadingedgepower com Page 45 of 48 Rev Q...
Page 46: ...Tel 44 0 1981 241668 www leadingedgepower com Page 46 of 48 Rev Q...
Page 47: ...Tel 44 0 1981 241668 www leadingedgepower com Page 47 of 48 Rev Q...