Stepper drive with speed control DM2282-IO-24 easy manual
!
Caution
Be sure to read this manual carefully before trying to install and use the product.
Be sure to check the connections and make sure the power lead polarity is correct, or there could result in injury or
fire.
Be sure to ground the earth terminal of the motor and drive without fail, or there could result in electrical shock.
Be sure to mount the load after making sure the motor work well without load,
or there could result in some
accident.
Be sure to turn off power and wait for 10 minutes or longer after LED display of the front panel has gone off, and
then you can transporting, wiring and inspecting the drive, or there could result in electrical shock or fire.
Be sure to install an emergency stop circuit externally so that you can stop the operation and shut off the power
immediately, or there could result in some accident.
Be sure to give the power supply voltage does not exceed the drive’s input range, or there could result in burning
out drive and motor.
Web:
Sales:
Support:
Peak
RMS
SW1
SW2
SW3
Default
off
off
off
2.2A
1.6A
on
off
off
3.2A
2.3A
off
on
off
4.2A
3.2A
on
on
off
5.2A
3.7A
off
off
on
6.3A
4.4A
on
off
on
7.2A
5.2A
off
on
on
8.2A
5.9A
on
on
on
Motor Speed (RPM)
SW5
SW6
SW7
SW8
100
on
on
on
on
150
off
on
on
on
250
on
off
on
on
350
off
off
on
on
450
on
on
off
on
550
off
on
off
on
650
on
off
off
on
750
off
off
off
on
850
on
on
on
off
950
off
on
on
off
1050
on
off
on
off
1150
off
off
on
off
1250
on
on
off
off
1350
off
on
off
off
1450
on
off
off
off
1500
off
off
off
off
DIP Switch Setting
●
DM2282-IO-24 has 8-bit DIP switches, functions as below:
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
●
Output current setting (3-bit)
●
Motor speed setting (4-bit)
Dynamic output current
Motor speed
Holding current/Auto-tuning
Note
:
This drive is only suitable for long-term constant
speed applications, not for applications with frequent
speed adjustment.
●
Holding current/Auto-tuning (SW4)
“Off” means holding current is 60% of dynamic current,
while “on” means 100%.
Switch “SW4” two times in two seconds will activate
parameter Auto-configuration for current loop.