User Manual for ELD2-CAN Servo
www.leadshine.com
84
Z signal
Start Position
Stop Position
High speed
6099h-01h
Low speed
6099h-02h
Method -1
:
Search the homing point with low speed positive direction, when the torque reached then reverse
the direction, when the torque is gone and Z signal coming then stop immediately.
Z signal
Start Position
Stop Position
High speed
6099h-01h
Low speed
6099h-02h
Method 1:
If the negative limit switch is invalid, the motor will move in negative direction at high speed until the
negative limit switch signal is valid. The motor stops and starts moving at low speed in positive direction. The
motor stops after leaving the negative limit switch and the first encoder Z signal is valid, as shown in figure.
If the motor stops at the negative limit position when it starts to move, the motor will move in positive
direction at low speed. The motor stops after leaving the negative limit switch and the first encoder Z signal is
valid, as shown in figure.
If the positive limit signal is valid during the homing process, the status word (6041h) bit 13 will be valid,
indicating that the homing error and the motor will stop immediately.
Z signal
NOT signal
A
B
Start Position
Stop Position
High speed
6099h-01h
Low speed
6099h-02h
Method 2:
If the positive limit switch is invalid, the motor will move in positive direction at high speed until the
positive limit switch signal is valid. The motor stops and starts moving at low speed in negative direction. The
motor stops after leaving the positive limit switch and the first encoder Z signal is valid, as shown in figure.
If the motor stops at the positive limit position when it starts to move, the motor will move in negative