2 Installation
2.1 Storage and Installation Conditions
2.1.1 Storage condition
Correctly packaged and store in a clean and dry environment where direct sunlight is
avoided.
Store within an ambient temperature ranging from -20
℃
to +65
℃
.
Store within a relative humidity ranging from 40% to 90% and non-condensed.
Avoid any type of exposure to corrosive gases.
2.1.2 Operating ambience conditions
Temperature ranging from 0
℃
to 40
℃
. The ambient temperature of drive for long-term
reliability should be under 40
℃
. Please install the drive in a well-ventilated area.
Operation within a relative humidity ranging from 40% to 90% and non-condensed.
Vibration lower than 0.15mm at a frequency of 10Hz-55Hz.
CAUTION
2.2 Mechanical Specification
Unit: mm,1inch=25.4mm
Figure 2.1: EM3E-522E/556E/870E Mechanical Drawing
2.3 Installation Direction and Space
The mounting of drive,wiring and motor should be under the regulations of EN 61800-5-1.
Incorrect installation may result in a drive malfunction or premature failure of the drive
and
/
or motor. Please follow the guidelines in this manual when installing
DO NOT mount the drive and motor in a location subjected to
corrosive or flammable gases,and combustibles.
Please mount the drive and motor in an indoor electric
control cabinet without liquid where direct sunlight is avoided.
DO NOT mount the drive and motor in a location subjected to
airborne dust.
Please ensure grounding wires are securely connected