EM3E Series EtherCAT Stepper Drive User Manual
56
02
Slow
homing
velocity
R/W/S
DINT
-2147483648
~2147483647
25000
P/S
Speed during search for
origin signal
607C
00
Home offset
R/W/S
DINT
-2147483648
~2147483647
0
P
The value of difference
between
senor
origin
position and mechanical
origin
position
under
Home mode
609A
00
Homing
acceleration
R/W/S
USIN
T
-2147483648
~2147483647
25000
P/S^2
Acc / Dec velocity under
Home mode
60B0
00
Position offset
R/W
DINT
-2147483648
~2147483647
0
P
Position offset under PP
mode
60B8
00
Touch
probe
control word
R/W
UINT
0-65535
0
-
Set touch probe function,
refer to chapter 6.3
60B9
00
Touch
probe
statue word
R
UINT
0-65535
0
-
Status of touch probe 1/2,
refer to chapter 6.3
60BA
00
Touch probe 1
positive value
R
DINT
-2147483648
~2147483647
0
P
Data value sensed by touch
probe 1 at rising edge
60BB
00
Touch probe 1
negative value
R
DINT
-2147483648
~2147483647
0
P
Data value sensed by touch
probe 1 at falling edge
60BC
00
Touch probe 2
positive value
R
DINT
-2147483648
~2147483647
0
P
Data value sensed by touch
probe 2 at rising edge
60BD
00
Touch probe 2
negative value
R
DINT
-2147483648
~2147483647
0
P
Data value sensed by touch
probe 2 at falling edge
60C2
1
01
Interpolation
time
period
value
R/W
USIN
T
0-255
2
--
Only for internal tuning.
02
Interpolation
time unit
R/W
SINT
-128-127
0
--
60D5
00
Touch probe 1
rising
edge
counter
R
UINT
0-65535
0
--
Frequency for capture of
touch probe 1 rising edge
60D6
00
Touch probe 1
falling
edge
counter
R
UINT
0-65535
0
--
Frequency for capture of
touch probe 1 falling edge
60D7
00
Touch
probe2
rising
edge
counter
R
UINT
0-65535
0
--
Frequency for capture of
touch probe 2 rising edge
60D8
00
Touch probe 2
falling
edge
counter
R
UINT
0-65535
0
--
Frequency for capture of
touch probe 2 falling edge
60FD
00
Digital
input
statue
R
UDIN
T
0-
4294967296
0
--
Statue
of
digital
input
signals, refer to chapter
4.3.1
60FE
01
Open
physical
output
R/W/S
UDIN
T
0-
4294967296
0
--
Able to control user output
through this object, refer to
chapter 4.3.4
02
Enable physical
output
R/W/S
UDIN
T
0-
4294967296
0
--
6502
00
Supported
operation mode
R
UDIN
T
0-
4294967296
165
--
Operation modes the drive
supported