Hardware
installation manual of the ES-DH series drives
11
Display Data Mode
This mode is active initially at drive
’
s power-up. In this mode, users can check the monitoring data as shown in the
following table.
Display Code
Name
Description
“
L
“
Low order digits display.
“
H
“
High order digits display.
“
d00uEP
”
Position error which is the difference between command and feedback.
Press
“
”
to switch between low and high order digits display.
“
d01SPF
”
Actual feedback motor speed in RPM.
“
d02SPr
”
Reference motor speed in RPM.
“
d03PLF
”
Actual feedback position in pulses.
“
d04PLr
”
Reference position in pulses.
“
d05iP
“
Reference current (peak) in mA.
“
d06Err
”
Error code:
0001----Over-current protection activated
0002----Over-voltage protection activated
0003----Brake protection activated
0004----Position error exceeds the limit
“
d07 Pn
”
Bus voltage which is 1/10 of the actual value.
“
d08 no
”
Drive version number.
www.servosystem.ru +7(495) 407-01-02