User Manual of iSV2-CAN Servo
www.leadshine.com
74
1
0
1
Homing error occurred;
Homing mode carried out not successfully;
Velocity is zero
1
1
x
Reserved
6.8.3 Related objects
Object Dictionary
Description
Setup value
Units
6060H
Mode of operation
-
6040H
Controlword
6041H
Statusword
6098H
Homing method
6099H
Homing speeds
Comma nd unit /s
609AH
Homing acceleration
Comma nd unit /s
2
607CH
Home offset
Comma nd unit
6.8.4 Example of homing mode
No
Command
Function
1
81 00 00 00 00 00 00 00
Reset all nodes. If you need to reset the specified node, the node
number is changed by modifying the two digits after 81 (note that it
is hexadecimal)
2
01 00 00 00 00 00 00 00
Start remote control for all nodes. If remote control of the specified
node needs to be started, the node number is changed by modifying
the two-digit number after 01 (note that it is hexadecimal).
3
2b
40 60
00 06 00 00 00
Write control word as 06
H
,
state machine switching status
Switch On Disabled->Ready to Switch On
4
2b
40 60
00 07 00 00 00
Read control word as 07H
,
state machine switching status
Ready to Switch On-> Switched On
The relay in the actuator is engaged at this point
5
2b
40 60
00 0f 00 00 00
Write control word as 0fH
,
state machine switching status
Switched On->Operation Enable. Servo-Enabled
6
2f
60 60
00 06 00 00 00
Write operation mode as 6H, homing mode
7
23
99 60
01 30 75 00 00
Write home speed-high speed as 7530H
(
180rpm, 10000p/r
)
8
23
99 60
02 20 4e 00 00
Write home speed-low speed as 4e20H
(
120rpm, 10000p/r
)
9
23
9a 60
00 30 75 00 00
Write the acceleration of home speed as 7530H
(
180rpm/s,10000p/r
)
10
2f
98 60
00 16 00 00 00
Write home method as 16H
(
The 22rd home method
)
11
2b
40 60
00 1f 00 00 00
Write the control word as 1f, set the 4th digit of 6040H as 1, start
homing mode.
12
2b
40 60
00 0f 00 00 00
Write the control word as 0f, and set the 4th digit of 6040H as 0, do
not start homing mode.