background image

 

4: Product Specifications 

 
This range of LEC refrigerators and freezers have been designed and built with the intention of the product 
being used within pharmacies, hospitals, and laboratories. 

Please see below for specific product information. 
 

Pharmacy Plus and Neonatal Range

 

Refrigerators 

SKU No 

Model 

Height 

(mm) 

Width 

(mm) 

Depth 

Inc

 

Handle

 

(mm) 

Weight 

(Kg) 

Rating 

(Amp) 

Power 

(W

)

 

Temperature 

Range 

Ambient 

Temperature 

Refrigerant 

444411305  PPSR47BT-UK 

565 

475 

445 

17.5 

 

0.60 

70 

2

to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411307  PPSR47BT-EU 

565 

475 

445 

17.5 

 

0.60 

70 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411306  PPGR47BT-UK 

565 

475 

445 

18.5 

 
 
 

0.60 

70 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411376  NSR47BT-UK 

565 

475 

445 

17.5 

 

0.60 

70 

2⁰C to 4⁰C

 

25⁰C to 32⁰C

 

R600a 

444411308  PPSR158BT-UK 

850 

595 

660 

33.3 

 
 

0.78 

101 

2

to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411311  PPSR158BT-EU 

850 

595 

660 

33.3 

 

0.78 

101 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411325  PPSR158BT-DWP-UK 

Boots 

850 

595 

660 

38.3 

 

0.78 

101 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411387  PPSR158BT-DWP 

850 

595 

660 

38.3 

 

0.78 

101 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411389  PPSR158BT-DLK 

850 

595 

660 

33.3 

 

0.78 

101 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411377  NSR158BT-UK 

850 

595 

660 

38.3 

 

0.78 

101 

2⁰C to 4⁰C

 

25⁰C to 32⁰C

 

R600a 

444411309  PPGR158BT-UK 

850 

595 

645 

36.3 

0.78 

101 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411310  PPGR158BT-LHH-UK 

850 

595 

645 

36.3 

0.78 

101 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411312  PPGR158BT-EU 

850 

595 

645 

36.3 

0.78 

101 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411388  PPGR158BT-DWP 

850 

595 

645 

39.3 

 
 

0.78 

101 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411390  PPGR158BT-DLK 

850 

595 

645 

36.3 

0.78 

101 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411313  PPSR310BT 

1560 

 
 

595 

660 

50.0 

 

0.65 

88 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411394  PPSR310BT-DWP 

1560 

 
 

595 

660 

58.0 

 

0.65 

88 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411391  PPSR310BT-DLK 

1560 

 
 

595 

660 

50.0 

 

0.65 

88 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411314  PPGR310BT 

1560 

 
 

595 

645 

60.0 

 

0.65 

88 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411315  PPGR310BT-LHH 

1560 

 
 

595 

645 

50.0 

 

0.65 

88 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411393  PPGR310BT-DWP 

1560 

 
 

595 

645 

68.6 

 

0.65 

88 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411392  PPGR310BT-DLK 

1560 

 
 

595 

645 

50.0 

 

0.65 

88 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411317  PPSR400BT 

1925 

 
 

595 

660 

61.8 

 

0.65 

88 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411398  PPSR400BT-DWP 

1925 

595 

660 

74.8 

0.65 

88 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411396  PPSR400BT-DLK 

1925 

595 

660 

61.8 

 

0.65 

88 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411316  PPGR400BT 

1925 

595 

645 

69.6 

 

0.65 

88 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411318  PPGR400BT-LHH 

1925 

595 

645 

61.8 

 

0.65 

88 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411397  PPGR400BT-DWP 

1925 

595 

645 

82.6 

 

0.65 

88 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

444411395  PPGR400BT-DLK 

1925 

595 

645 

61.8 

 

0.65 

88 

2⁰C to 8⁰C

 

16⁰C to 32⁰C

 

R600a 

 

 

 

 

Summary of Contents for 444411305

Page 1: ...0 083870100 Rev05 27 07 22 www lec medical co uk USER MANUAL The Experts in Medical Refrigeration Pharmacy Plus Laboratory Plus Pharmacy Connect Operating Instructions...

Page 2: ...tall the LEC Medical App 17 9 2 Connecting to an appliance 17 9 3 App Home Page 18 9 6 Accessing Min Max temperatures 18 9 5 Re Setting Min Max Temperatures using the APP 19 9 7 Re Naming the Applianc...

Page 3: ...2 PPGR310BT DLK 400 444411317 PPSR400BT 444411398 PPSR400BT DWP 444411396 PPSR400BT DLK 444411316 PPGR400BT 444411318 PPGR400BT LHH 444411397 PPGR400BT DWP 444411395 PPGR400BT DLK Pharmacy Connect 158...

Page 4: ...T UK Range Vol L SKU No Model Laboratory Plus 158 444411358 LSFSR158BT UK 444411359 LSFSR158BT EU 310 444411360 LSFSR310BT UK 444411361 LSFSR310BT UK ATEX 400 444411364 LSFSR400BT 444411365 LSFSR400BT...

Page 5: ...warning labels carefully Failure to follow these instructions may cause this product to malfunction which could result in injury or damage WARNING Potentialdanger of electric shock which if not avoid...

Page 6: ...ot use mechanical devices or other means to accelerate the defrosting process other than those recommended by the manufacturer Energy Saving Tips This equipment uses energy efficient R600a refrigerant...

Page 7: ...1 2 C to 8 C 16 C to 32 C R600a 444411310 PPGR158BT LHH UK 850 595 645 36 3 0 78 101 2 C to 8 C 16 C to 32 C R600a 444411312 PPGR158BT EU 850 595 645 36 3 0 78 101 2 C to 8 C 16 C to 32 C R600a 444411...

Page 8: ...CSR400CT DLK 1925 595 660 62 8 0 65 88 2 C to 8 C 16 C to 32 C R600a 444411339 PCSR400CT DWP 1925 595 660 75 8 0 65 88 2 C to 8 C 16 C to 32 C R600a 444411334 PCGR400CT 1925 595 645 70 6 0 65 88 2 C t...

Page 9: ...efrigerators freezers are designed for use in general laboratory locations FMS units are NOT designed for use in Class I Zone 0 or Zone1 applications which require an Explosion Proof Refrigerator Free...

Page 10: ...9 5 Product Details 5 1 Pharmacy Plus Refrigerators...

Page 11: ...10 Product Details cont 5 2 Laboratory Plus Refrigerators...

Page 12: ...11 Product Details cont 5 3 Laboratory Plus Freezers...

Page 13: ...12 Product Details cont 5 4 Laboratory Plus Refrigerator Freezer Combi...

Page 14: ...ent equipment or parts Before use confirm that the product has not been altered in anyway Your unit must be properly grounded in conformity with national and local electrical codes Never connect the u...

Page 15: ...he alarm is signalized by a sound signal and Hi caption on the display To mute the alarm touch anywhere on the front surface of the controller Until the moment of cooling the alarm is repeated every 1...

Page 16: ...to switching on This equipment is not intended for use by persons including children with reduced physical sensory mental capabilities or lack of experience and knowledge unless they have been given s...

Page 17: ...on If this symbol is displayed the controller is in an alarm condition It will clear when the alarm fault is cleared Evaporator Fan Running Indicates when the evaporator fan is running under the intel...

Page 18: ...natively open the App Store Play Store and search for Lec Medical Install and open the app connect to the appliance 9 2 Connecting to an appliance Open the app the first window will list of all availa...

Page 19: ...d time of the last reset is displayed below LAST RESET after RESET the current Air and Load temperatures will be displayed NOTE After pressing RESET the Min Max temperatures are stored in the controll...

Page 20: ...hly recommends renaming the appliance to a name of your choice particularly if more the one LEC Medical Bluetooth enabled appliance is present To rename the Appliance press the WHITE TEXT button next...

Page 21: ...2 2 When connected the home screen will be displayed as shown below 3 To change the SET POINT press the current SET POINT temperature displayed in white 4 The SET POINT window will be displayed 5 Key...

Page 22: ...ill be as it was at the point of disconnection If the status of controller is OFF the controller will display alternating OFF and the current AIR LOAD temperature If the status of controller is ON the...

Page 23: ...22 10 Advanced Operations using the LEC Medical App...

Page 24: ...iew the max and min temperature Press to display the max temperature press again to return to current temperature Press to display the min temperature press again to return to current temperature 3 Se...

Page 25: ...S Press Navi button to confirm RESET Controller returns to LOC Status Both air and load maximum and minimum temperatures will be RESET Please note The Minimum and Maximum temperatures are stored in th...

Page 26: ...on Press Navi button Press or to enter USER PASSWORD 11 Press Navi button Press Navi button Press Navi button Press or to change to set point Press Press Navi button Press Navi button return to LOC St...

Page 27: ...26 12 Alarm Status...

Page 28: ...27 13 Trouble Shooting...

Page 29: ...al laws of that State at the time of disposal As this item is designed for medical use before presenting for collection and disposal it will be necessary for the user to provide documentary evidence o...

Page 30: ...ies Email marketing gdpa co uk Tel 0344 815 3742 Spares and After Sales Service Email info gdha com Tel 0344 815 3742 Fax 0844 248 4123 Address Lec Medical Stoney Lane Prescot Merseyside L35 2XW Warra...