background image

The manufacturer is exempt from all liability arising from non-compliance with the procedures con-
tained in this manual.

• 

GAS CONDENSER

  The incorrect maintenance and lack of cleaning of the gas condenser of the refrigerated unit can 

considerably reduce the performance of the unit as well as shortening the life of the compressor 
motor. The cleaner the unit, especially the condenser fins, 

the greater the energy saving

.

  In any event, it is recommended that this task is 

carried out by a service technician

. In the case of 

any doubt, please contact your distributor.

  The cleaning of the gas condenser must be carried out with the unit unplugged and removing the 

protectors (grills) or taking out the condenser unit (depending on the model).

In order to remove the dirt deposited between the condenser fins, any of the following procedures 
are recommended:

  • Use a toothbrush or soft-bristle brush
  • Blow the dirt using a suitable appliance
  • Use air pressure to remove the dirt

We recommend that this operation is carried out at least 
once every three months and at the start of every sum-
mer.

• 

EVAPORATORS

 

Only for specialist personnel

  The only maintenance the evaporators require is proper cleaning. This has to be done with the 

machine stopped and once the ice that may be present on the fins has melted or once defrosting 
has been done by operating the controls. This process may be accelerated by using warm water, 

NEVER

 using hard or sharp objects. 

  In order to clean the coil or the casing, 

DO NOT

 use chemical de-greasers with acid compounds 

or bleach, chlorine, ammonia or salts as all these products aggressively attack copper and alu-
minium. Only water with well-diluted neutral detergents should be used or products especially 
designed for cleaning the evaporators of refrigerated units. The cleaner the unit, 

the greater the 

energy saving

.

• 

AUTOMATIC EVAPORATION TRAY

  Only for specialist personnel

  The majority of the units are equipped with an automatic evaporation tray for the situations where 

an external outlet is not available to collect the defrosted water from the evaporators. If this tray 
is not included, the drainage tubes have to be connected directly to the appropriate device or a 
receptacle should be positioned in order to collect the water.

  The defrost water can also cause breakdowns as the piping that brings the heat necessary for the 

water to evaporate can be punctured or the electrical resistance can deteriorate.

  Attention should be given to this tray and regular cleaning is recommended.

• 

DOOR SEALS

           www.lec-commercial.co.uk  

     

10

 

Summary of Contents for 444443640

Page 1: ...44443646 SOC 1525MM 444443647 SOC 2025MM 444443648 PC2DR 444443649 PC3DR 444443650 PCT 1345MM 444443651 PCT 1795MM 444443652 PCT 2245MM 444443653 SALADETTE2DR SG 444443654 SALADETTE2DR LID 444443655 SALADCTR2DR 444443656 SALADCTR3DR 444443657 SLMFRIDGE 444443658 SLMFREEZER 444443659 GFSDR 444443660 GFGDR 444443661 BD2DR 444443662 BD3DR 444443663 BD4DR ...

Page 2: ......

Page 3: ...t www lec commercial co uk Simply click on the Our Warranty tab located towards the top of the page and then choose the Activate Warranty option from the drop down menu In the unlikely event of breakdown please contact us on 0844 815 3755 and choose the After Sales option for assistance Remember You will need to quote the serial number of this unit This can be found on the data plate of the applia...

Page 4: ...nce manual together with the re gistration number of the unit In the event of loss please request a duplicate indicating the model serial number and date of purchase Before carrying out any operation whether as installation technician or as the user of the unit you should be aware of the points explained in this manual The manufacturer considers that both the installation technician and the user o...

Page 5: ... conditions other than those established in this manual and the details of each model contained in the catalogue failure in the power supply high ambient temperatures windows lighting etc 3 INSTALLATION AND ASSEMBLY The unit must not be moved from its standard vertical position however as necessary some applian ces may be placed face down only as indicated on the packaging You are advised to unpac...

Page 6: ...an and dry place the accessories in their proper places ATTENTION Please do not use steel wire or nickel sponges to clean STAINLESS STEEL or leave them lying on the surface as the iron deposits can stick and cause the formation of rust contamination thus jeopardi sing the hygiene of the surface www lec commercial co uk 4 ...

Page 7: ...VAPORATORS AUTOMATIC EVAPORATION TRAY DOOR SEALS 9 OPERATIONAL TESTS CHECKS IN THE EVENT OF OPERATIONAL FAILURE NOISE TESTS 10 MANUFACTURING ELEMENTS REFRIGERANT COMPOSITION OF THE THERMAL INSULATION instructions for use Initial Notice Before turning the unit on we recommend you to read the instructio ns and follow the steps as explained www lec commercial co uk 5 ...

Page 8: ...re not defects on the unit resulting from its transportation The manufacturer will not be liable for damage suffered during transportation or arising from incorrect storage Check the operation of the moving components of the unit Check the safety of the control board electrical cables and connections Check that all the interior and additional accessories are present 2 GENERAL CONNECTIONS Before co...

Page 9: ... the LED showing the compressor is working will light up permanently The initial temperature that is shown on the thermostat display will be the ambient temperatu re As the machine works the temperature will reduce until it reaches its operating temperatu re The units for storage of frozen foods are programmed to defrost two hours after starting opera tion It is important that the unit runs until ...

Page 10: ...ance with the observation described in the above point The units designed for the storage of frozen foods are suitable for the conservation of frozen foods and not for freezing the product The operational limits established for the units are shown by climatic category REFRIGERATION 0ºC to 10 C FROZEN FOOD STORAGE 25ºC to 15 C FISH COMPARTMENT 6ºC to 2ºC Prepared to conserve fresh products or pre c...

Page 11: ...owever leaning on the doors is completely prohibited In those units equipped with metallic drawers it is not advisable to load them with more than 30kg weight per drawer or 25kg in plastic boxes ensuring in all cases that the load is uniformly distributed For this reason sitting or leaning on the drawers is not allowed Do not remove the protection from the movable components without having previou...

Page 12: ...proper cleaning This has to be done with the machine stopped and once the ice that may be present on the fins has melted or once defrosting has been done by operating the controls This process may be accelerated by using warm water NEVER using hard or sharp objects In order to clean the coil or the casing DO NOT use chemical de greasers with acid compounds or bleach chlorine ammonia or salts as al...

Page 13: ... The internal temperature is too high Check that there is no heat source nearby Check that the grill is not obstructed In order to check the cut off point of the thermostat press the set button once then release Check that the product loaded is perfectly distributed without blocking the interior air ventilation exits and that the time elapsed since loading has been sufficient to chill the products...

Page 14: ...ll fastenings nuts and bolts which will be made of stainless or zinc based steel The refrigerated unit is designed to be operated using ecological gas refrigerant approved by the current EC standards REFRIGERANT REFRIGERATION R134a or R404A FREEZING R404A COMPOSITION OF THERMAL INSULATION The thermal insulation is made from expanded polyurethane 40 kg m 3 using the substance R 134a as the expandin...

Page 15: ......

Page 16: ...nfo gdpa co uk tel 0844 815 3755 Opt 3 fax 0844 248 4123 Marketing Enquiries email marketing gdpa co uk tel 0844 815 3755 Opt 5 For all International Non UK Enquiries email info gdpa co uk tel 44 151 493 3281 fax 44 151 432 7082 Address Glen Dimplex Professional Appliances Stoney Lane Prescot Merseyside L35 2XW For any other information please visit www lec commercial co uk ...

Reviews: