   Section 2b – 

INSTALLATION 

 

 

 

AC 

Plug 

Line In 

 

 

 

Electrical Connections 

Control Box Connections 

Autopilot recommends that a licensed electrician or certified electrical contractor perform the electrical connections.  

DANGER: ensure that the electrical panel or filter pump circuit breaker is turned OFF before wiring this unit.  

Your 

Lectranator Soft Touch Model ST 48 

Control Box comes pre-wired from the factory for 230VAC (1.5 amps max draw) and can also 

operate on 115 VAC, (3.0 amps max draw) at 50/60Hz.  1.8m (6ft.) of AC lead wires are provided with the unit and are located on the bottom 
base plate of the control box along with the Cell, Tri-Sensor and optional ORP Interface connections. 

Converting to 115VAC 

is accomplished by accessing the circuit board, rewiring, and attaching the included jumper as shown below. 

Remove the cover (see page 10) to access and ensure that the Jumper Connections on the circuit board marked “TRANSFORMER 
PRIMARY” are matched to the LINE IN voltage.  Follow all state/local codes for electrical installations. 

 

?  An additional jumper is 

Power Circuit Board 

provided with your 
Installation Kit for 115VAC. 

Transformer 

Location of the 
Input Jumper Connections 

 

230 VAC 

115 VAC 

INNER CONTROLPANEL 

FACTORY SETTING 

WIRING DIAGRAM 

 

Top terminals factory wired – do not disturb. 

AC to PCB 

Bonding 

6-pin Tri-sensor 

Lug 

  connector 

 

#1  #2  #3  #4  #5  #6 

Ground 

Conduit 

Lugs 

connector 
provided 

(Gr/Yel) (Br) (Bl) 

 

Lectranator Soft Touch Model ST 48 AC Line IN 

AC LINE IN 

(Wiring diagram also located on inside of cover)

 

 

 

 

2-pin ORP 

Connector 

CONTROL BOX BASE PLATE 

 
 

 

Cell Cord 
Connectors 

For 230 VAC

; Brown (Br) = Line 1, Blue (Bl) = Line 2, Green w/Yellow Tracer (Gr/Yel) = Earth Ground  

For 115 VAC

; Brown (Br) = Line, Blue (Bl) = Neutral, Green w/Yellow tracer (Gr/Yel) = Earth Ground  

The AC Line IN wiring is pre-set for connection to the 

LINE SIDE

of your time clock, electronic controller switch or relay to work 

in conjunction with your circulation pump. 

 

Cell Cord

Each Cell Cord contains (2) Banana Plugs that attach to the (2) Banana Jacks on the bottom of the Control Box. 

Polarity does not matter. The other end of the cell cord has a three-position plug that connects to the cell in any direction. See page 
11 for service instructions. 

 

Tri-Sensor Cord

The Tri-Sensor Cord connects to the keyed 6-pin harness on the Control Box Base Plate. The opposite end of 

the cord connects to the Tri-Sensor Assembly with a locking ring quick connect. Align the grove and keyway on the connector and 
twist the locking ring to ensure a proper connection. Refer to the instructions on pages 10 & 12 for diagrams and additional 
instructions. 

 

ORP Connection

When an ORP Chemical Controller is interfaced to your 

Lectranator Soft Touch Model ST 48

, the Chemical Controller 

will remotely control the SANITIZER Output.  Adjust the output level to 0% and connect the ORP controller to the 2-pin connector 
on the Control Box Base Plate. When the ORP is activated, the output will indicate ON with the display showing 0%.  

WARNING: THE ORP CONNECTIONS ARE DRY CONTACT INPUTS, DO NOT ENERGIZE THESE 

INPUTS!  DAMAGE TO THE CONTROL BOX WILL OCCUR AND WILL VOID THE WARRANTY. 

Plug 

TRANSFORMER PRIMARY 

TAB 4 

TAB 3 

115VAC 

TAB 6 

TAB 5 

TAB 8 

TAB 7 

115VAC 

fffffffffff 

TAB 10 

TAB 9 

TRANSFORMER PRIMARY 

TAB 4 

TAB 3 

TAB 6 

TAB 5 

230VAC 

TAB 8 

TAB 7 

TAB 10 

TAB 9 

Summary of Contents for ST 48

Page 1: ...REN DOMESTIC READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN Imported to Canada by LECTRANATORSYSTEMSINC 1034 72 Avenue N E Calgary Alberta T2E 8V9 Phone 1 866 517 7584 REGISTRATION NO 27841 PEST CONTROL PRODUCTS ACT LECTRANATOR SOFT TOUCH MODEL ST48 Chlorine or Bromine Generating Device One ST48 unit can treat a maximum of 153 000 Liters of swim...

Page 2: ...NTROL PRODUCTS ACT and Lectranator Digital Model DIG 48 REGISTRATION NUMBER 27844 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine or bromine generating device Read the Label and the Installation and Operation Manual of the chlorine or bromine generating device Lectranator Soft Touch Model ST48 or Lectranator Digital Model DIG 48 before using Lectranator Systems In...

Page 3: ... Bacteria And Algae In Swimming Pool Waters For Indoor or Outdoor use RETAIN MANUAL FOR FUTURE REFERENCE C NSF50 IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING NOTICE TO USER This pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Product Act to use this product in a way that is inconsistent with the ...

Page 4: ...___ Cell Model Number RC 7 Lectranator Soft Touch Model ST 48 by LECTRANATOR SYSTEMS INC Record The Following Information Factory Direct Customer Assistance HOTLINE 1 866 517 7584 or 1 403 291 9845 FAX 1 403 291 1023 Visit Us On The Internet http www lectranator com Manufactured for Lectranator Systems Inc 1034 72 Avenue N E Calgary Alberta T2E 8V9 Lectranator Soft Touch Model ST 48 by LECTRANATOR...

Page 5: ...cordance with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product Children should not use spas hot tubs or pools without permanent adult supervision Equipment Related 115 230VAC 50 60 Hz Models fixed wiring 1 A wire connector is provided on your Lectranator Soft Touch Model ST 48 to connect a minimum 8 4 mm No 8 AWG in the U S A and 6 3mm No...

Page 6: ...ord and Tri Sensor Connections ORP Connections 2c Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Control Panel 7 3b Pool Water Preparation 8 Salt Requirement Chart Start Up Procedures 8 3c Monitoring and Maintenance 9 Water Chemistry Parameters Saturation Index Section 4 SERVICE and MAINTENANCE 4a Servicing 10 Control Box Tri Sensor 4b...

Page 7: ...er by following the steps pool or spa instructions to remove and inspect on page 10 to access the mounting See page 8 for salt requirements the tri sensor assembly holes to tighten the screws RATINGS Input Power 115 VAC 3 0 AC amps MaximumOutput Equivalentto0 75kg 1 65 lbs offreeavailable chlorine day 230 VAC 1 5AC amps RC 7 CELL Cell Power Level 3 8 amps DC 50 60 Hz Cell Life Expectancy A minimum...

Page 8: ... PLATE Cell Cord Connectors For 230 VAC Brown Br Line 1 Blue Bl Line 2 Green w Yellow Tracer Gr Yel Earth Ground For 115 VAC Brown Br Line Blue Bl Neutral Green w Yellow tracer Gr Yel Earth Ground The AC Line IN wiring is pre setfor connection to the LINE SIDEof your time clock electronic controller switch or relay to work in conjunction with your circulation pump Cell Cord Each Cell Cord contains...

Page 9: ...ollowing this procedure to verify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or equipment damage Using either a GOLF BALL or small plastic wrap saran wrap food wrap or zip lock bag block off flow to the upper portion of the manifold by placing the golf b...

Page 10: ...ogrammed Cell Power and Reversing settings Test your water chemistry parameters monthly and compare to the Saturation Index WARNING Changingthe Reversingcycle toSHORTwillalsoreduce celllife However operatingthecell underscaledconditions on Normal or Long is more detrimental to the life of the cell and changingthe Reverse cycle is suggested The BOOST Buttonactivates the Boost light when it is press...

Page 11: ...m purity of 99 Sodium Chloride NaCl NOTE Do not use Rock Salt due to its high levels of impurities TEST YOUR WATER FOR SALT LEVEL FIRSTwith the provided salt test strips and then use the chart below to determine the amount of salt to add SALT REQUIREMENT CHART KILOS LBS OF SALT NEEDED FOR 3000 PPM RESIDUAL SALT Level Before Addition Pool Volume in Liters US Gallons 3 780 1 000 9 430 2 500 18 900 5...

Page 12: ...nuric acid levels at the same time as your salt level as these tend to deplete at the same rate Regulations may exist regarding the use of cyanuric acid please consult your local authority NOTE For Bromine or indoor pools it is not necessary to add stabilizer SALT RESIDUAL Your Lectranator Soft Touch Model ST 48 works most efficiently with salt levels between 2 8 3 2 g l 2800 3200 ppm If it fallsb...

Page 13: ...tions remove these board removes with cover fuses and pump aux relay TRI SENSOR ASSEMBLY The Tri sensor assembly tests for Flow Salt and Water temperatures A minimum flow rate of94 5 L min 25 US Gallons min is required to activate the flow switch As the water flow closes the paddle a magnet activates a micro switch to verify proper flow The Salt sensor protects against lowsalt levels and the tempe...

Page 14: ... a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution ina containerhighenough tocoverthe Cellblades You may also use TABEXLectraClean non fuming pre mixed cell cleaner per label directions Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes An effervescences action indicates the calcium is being neutrali...

Page 15: ...ions and Cord ordered separately Red Cap Plug for RC 7 cell cord 19050 12ft 3 6m Cell Cord 952 1 Union O Ring 19013 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Union Tri Sensor Assembly Cord Ordered Separately DirectionalFlowIndicator View of locking Quick connect heads 12ft 3 6m Tri Sensor Cord 956 DIG Tri Sensor O Ring 19028 Temperature Sensor Post Salt S...

Page 16: ...See Section 2 above C Cell Power selection not matched to the Cell installed C Follow the SETUP procedures to match the cell see page 7 5 White Flakes in the Water A This occurs when excessive calciumhardness is A Visually inspect Cell for scale build up and clean the cell as present Usually due to waterchemistry imbalance described on page 11 Adjust your water chemistry 6 No Power to the Control ...

Page 17: ... 3 lights In the case of salt the top light is not used the next to the top flashes the 1000 s digit and the third light flashes the 100 s digit in ppm Example 2 flashes pause 8 flashes pauseRead 2 800 PPM 2 Thesecondvalue is the watertemperaturein degrees Fahrenheit When this is displayed the second light from the bottom is on The top light flashes the 100 s digit the next the 10 s digit and the ...

Page 18: ......

Reviews: