   Section 4b 

–SERVICE and MAINTENANCE 

 

11 

 

 

-7 

RC 

Cell 

 

The Cell is installed with Unions on each end of the cell to allow quick and easy removal. Loosen the unions and remove the cell 
from the plumbing. 

 
 
 
 
 
 

 

Side View of Cell and Unions 

VISUAL CELL INSPECTION: 

The titanium Cell blades, seen inside the Cell body, should be straight and clear of any debris between the blades. Yo ur 

Lectranator Soft 

Touch Model ST 48 

is designed to automatically self-clean calcium scale build-up within the Cell. However, imbalanced water chemistry and 

certain conditions can cause a heavier scale build up that exceeds the self-cleaning capability and would need to be cleaned manually 
by the method described below. 

 

Periodically inspect both ends of the cell. 
A White Flaky or Crusty build-up on the 
edge or between the blades will prematurely 
deplete the life of the cell. Immediately 

End View of cell 

clean the cell and determine the cause of 

Looking at the Titanium Blades 

scaling. See Troubleshooting Section, page 13. 

 

MANUAL CELL CLEANING: 

With the Cell removed as described above, use a high-pressure hose nozzle to spray off as much loose, soft scale and debris as 
possible. Any remaining calcium scale can be treated with a mixture of one (1) part Muriatic Acid into four (4) parts water. Mix the 
solution in a container high enough to cover the Cell blades. You may also use 

TABEX LectraClean™ (

non-fuming/pre-mixed) cell 

cleaner, per label directions. 
Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes. An  
effervescences action indicates the calcium is being neutralized and cleaned. Drain the cell, flush with fresh water and re-inspect. 
Repeat the immersion if necessary. Once the cell has been cleaned and rinsed; it may be re-installed in-line. BE SURE THAT THE 
CELL “PINS” ARE CLEAN AND DRY BEFORE ATTACHING THE DC CORD FROM THE POWER SUPPLY. 

WARNING: 

ALWAYS ADD ACID TO WATER, never water to acid. 

When replacing the cell, only use replacement cells having a label that clearly states that it is a replacement cell for the chlorine or bromine 
generating device Lectranator Soft Touch Model ST48, REGISTRATION NUMBER 27841, PEST CONTROL PRODUCTS ACT. 

 

WARNING: ALWAYS ADD ACID TO WATER, never water to acid. 
NEVER USE ANY SHARP OR METALLIC OBJECTS TO REMOVE SCALE.  Scraping or scratching the titanium blade’s 
edge or surface will allow chemical attack of the blade, cause premature failure of the Cell and will void your warranty. 

 

Hacksaw Blades 

Screwdrivers 

Forks 

Knives 

 

 

FILTER BACKWASHING: 

The Control Panel Output setting must be set to 0% (OFF) when backwashing the filter.  

Summary of Contents for ST 48

Page 1: ...REN DOMESTIC READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN Imported to Canada by LECTRANATORSYSTEMSINC 1034 72 Avenue N E Calgary Alberta T2E 8V9 Phone 1 866 517 7584 REGISTRATION NO 27841 PEST CONTROL PRODUCTS ACT LECTRANATOR SOFT TOUCH MODEL ST48 Chlorine or Bromine Generating Device One ST48 unit can treat a maximum of 153 000 Liters of swim...

Page 2: ...NTROL PRODUCTS ACT and Lectranator Digital Model DIG 48 REGISTRATION NUMBER 27844 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine or bromine generating device Read the Label and the Installation and Operation Manual of the chlorine or bromine generating device Lectranator Soft Touch Model ST48 or Lectranator Digital Model DIG 48 before using Lectranator Systems In...

Page 3: ... Bacteria And Algae In Swimming Pool Waters For Indoor or Outdoor use RETAIN MANUAL FOR FUTURE REFERENCE C NSF50 IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING NOTICE TO USER This pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Product Act to use this product in a way that is inconsistent with the ...

Page 4: ...___ Cell Model Number RC 7 Lectranator Soft Touch Model ST 48 by LECTRANATOR SYSTEMS INC Record The Following Information Factory Direct Customer Assistance HOTLINE 1 866 517 7584 or 1 403 291 9845 FAX 1 403 291 1023 Visit Us On The Internet http www lectranator com Manufactured for Lectranator Systems Inc 1034 72 Avenue N E Calgary Alberta T2E 8V9 Lectranator Soft Touch Model ST 48 by LECTRANATOR...

Page 5: ...cordance with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product Children should not use spas hot tubs or pools without permanent adult supervision Equipment Related 115 230VAC 50 60 Hz Models fixed wiring 1 A wire connector is provided on your Lectranator Soft Touch Model ST 48 to connect a minimum 8 4 mm No 8 AWG in the U S A and 6 3mm No...

Page 6: ...ord and Tri Sensor Connections ORP Connections 2c Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Control Panel 7 3b Pool Water Preparation 8 Salt Requirement Chart Start Up Procedures 8 3c Monitoring and Maintenance 9 Water Chemistry Parameters Saturation Index Section 4 SERVICE and MAINTENANCE 4a Servicing 10 Control Box Tri Sensor 4b...

Page 7: ...er by following the steps pool or spa instructions to remove and inspect on page 10 to access the mounting See page 8 for salt requirements the tri sensor assembly holes to tighten the screws RATINGS Input Power 115 VAC 3 0 AC amps MaximumOutput Equivalentto0 75kg 1 65 lbs offreeavailable chlorine day 230 VAC 1 5AC amps RC 7 CELL Cell Power Level 3 8 amps DC 50 60 Hz Cell Life Expectancy A minimum...

Page 8: ... PLATE Cell Cord Connectors For 230 VAC Brown Br Line 1 Blue Bl Line 2 Green w Yellow Tracer Gr Yel Earth Ground For 115 VAC Brown Br Line Blue Bl Neutral Green w Yellow tracer Gr Yel Earth Ground The AC Line IN wiring is pre setfor connection to the LINE SIDEof your time clock electronic controller switch or relay to work in conjunction with your circulation pump Cell Cord Each Cell Cord contains...

Page 9: ...ollowing this procedure to verify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or equipment damage Using either a GOLF BALL or small plastic wrap saran wrap food wrap or zip lock bag block off flow to the upper portion of the manifold by placing the golf b...

Page 10: ...ogrammed Cell Power and Reversing settings Test your water chemistry parameters monthly and compare to the Saturation Index WARNING Changingthe Reversingcycle toSHORTwillalsoreduce celllife However operatingthecell underscaledconditions on Normal or Long is more detrimental to the life of the cell and changingthe Reverse cycle is suggested The BOOST Buttonactivates the Boost light when it is press...

Page 11: ...m purity of 99 Sodium Chloride NaCl NOTE Do not use Rock Salt due to its high levels of impurities TEST YOUR WATER FOR SALT LEVEL FIRSTwith the provided salt test strips and then use the chart below to determine the amount of salt to add SALT REQUIREMENT CHART KILOS LBS OF SALT NEEDED FOR 3000 PPM RESIDUAL SALT Level Before Addition Pool Volume in Liters US Gallons 3 780 1 000 9 430 2 500 18 900 5...

Page 12: ...nuric acid levels at the same time as your salt level as these tend to deplete at the same rate Regulations may exist regarding the use of cyanuric acid please consult your local authority NOTE For Bromine or indoor pools it is not necessary to add stabilizer SALT RESIDUAL Your Lectranator Soft Touch Model ST 48 works most efficiently with salt levels between 2 8 3 2 g l 2800 3200 ppm If it fallsb...

Page 13: ...tions remove these board removes with cover fuses and pump aux relay TRI SENSOR ASSEMBLY The Tri sensor assembly tests for Flow Salt and Water temperatures A minimum flow rate of94 5 L min 25 US Gallons min is required to activate the flow switch As the water flow closes the paddle a magnet activates a micro switch to verify proper flow The Salt sensor protects against lowsalt levels and the tempe...

Page 14: ... a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution ina containerhighenough tocoverthe Cellblades You may also use TABEXLectraClean non fuming pre mixed cell cleaner per label directions Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes An effervescences action indicates the calcium is being neutrali...

Page 15: ...ions and Cord ordered separately Red Cap Plug for RC 7 cell cord 19050 12ft 3 6m Cell Cord 952 1 Union O Ring 19013 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Union Tri Sensor Assembly Cord Ordered Separately DirectionalFlowIndicator View of locking Quick connect heads 12ft 3 6m Tri Sensor Cord 956 DIG Tri Sensor O Ring 19028 Temperature Sensor Post Salt S...

Page 16: ...See Section 2 above C Cell Power selection not matched to the Cell installed C Follow the SETUP procedures to match the cell see page 7 5 White Flakes in the Water A This occurs when excessive calciumhardness is A Visually inspect Cell for scale build up and clean the cell as present Usually due to waterchemistry imbalance described on page 11 Adjust your water chemistry 6 No Power to the Control ...

Page 17: ... 3 lights In the case of salt the top light is not used the next to the top flashes the 1000 s digit and the third light flashes the 100 s digit in ppm Example 2 flashes pause 8 flashes pauseRead 2 800 PPM 2 Thesecondvalue is the watertemperaturein degrees Fahrenheit When this is displayed the second light from the bottom is on The top light flashes the 100 s digit the next the 10 s digit and the ...

Page 18: ......

Reviews: