Section 4b
–SERVICE and MAINTENANCE
11
-7
RC
Cell
The Cell is installed with Unions on each end of the cell to allow quick and easy removal. Loosen the unions and remove the cell
from the plumbing.
Side View of Cell and Unions
VISUAL CELL INSPECTION:
The titanium Cell blades, seen inside the Cell body, should be straight and clear of any debris between the blades. Yo ur
Lectranator Soft
Touch Model ST 48
is designed to automatically self-clean calcium scale build-up within the Cell. However, imbalanced water chemistry and
certain conditions can cause a heavier scale build up that exceeds the self-cleaning capability and would need to be cleaned manually
by the method described below.
Periodically inspect both ends of the cell.
A White Flaky or Crusty build-up on the
edge or between the blades will prematurely
deplete the life of the cell. Immediately
End View of cell
clean the cell and determine the cause of
Looking at the Titanium Blades
scaling. See Troubleshooting Section, page 13.
MANUAL CELL CLEANING:
With the Cell removed as described above, use a high-pressure hose nozzle to spray off as much loose, soft scale and debris as
possible. Any remaining calcium scale can be treated with a mixture of one (1) part Muriatic Acid into four (4) parts water. Mix the
solution in a container high enough to cover the Cell blades. You may also use
TABEX LectraClean™ (
non-fuming/pre-mixed) cell
cleaner, per label directions.
Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes. An
effervescences action indicates the calcium is being neutralized and cleaned. Drain the cell, flush with fresh water and re-inspect.
Repeat the immersion if necessary. Once the cell has been cleaned and rinsed; it may be re-installed in-line. BE SURE THAT THE
CELL “PINS” ARE CLEAN AND DRY BEFORE ATTACHING THE DC CORD FROM THE POWER SUPPLY.
WARNING:
ALWAYS ADD ACID TO WATER, never water to acid.
When replacing the cell, only use replacement cells having a label that clearly states that it is a replacement cell for the chlorine or bromine
generating device Lectranator Soft Touch Model ST48, REGISTRATION NUMBER 27841, PEST CONTROL PRODUCTS ACT.
WARNING: ALWAYS ADD ACID TO WATER, never water to acid.
NEVER USE ANY SHARP OR METALLIC OBJECTS TO REMOVE SCALE. Scraping or scratching the titanium blade’s
edge or surface will allow chemical attack of the blade, cause premature failure of the Cell and will void your warranty.
Hacksaw Blades
Screwdrivers
Forks
Knives
FILTER BACKWASHING:
The Control Panel Output setting must be set to 0% (OFF) when backwashing the filter.