Page 8

total active energy

1

Function / Description

Order

Display

(example)

2

import active energy

export active energy

3

total resettable energy

4

Summary of Contents for Eastron SDM230M-DI

Page 1: ...User Manual Energy Meter ...

Page 2: ...ergy Meter The Lectron Energy Meter allows you to measure how much electricity is used by your Lectron V BOX Charging Station Warnings 1 During normal operation hazardous voltages may be present in some of the terminals of this unit Always use with caution ...

Page 3: ... in a dry and safe environment 1 Installation should only be done by a qualified professional following all local regulations 2 This energy meter should never be used as the sole means of fault protection 3 Install this energy meter after your main power supply 4 Only use this energy meter with the Lectron V BOX charging station Disclaimer ...

Page 4: ...easurement value 2 total value 3 import export energy 4 maximum demand loading current 5 PF power factor Hz frequency 6 measurement of kVArh reactive power measurement of kWh active power 7 power level 8 time duration 9 lock device ...

Page 5: ...Page 4 How to Install Install the energy meter by connecting it between your electrical panel and your V BOX 1 Connect the ground wire from the electrical panel to the V BOX ground ...

Page 6: ...pen the top compartment and tighten the screw using a Phillips screwdriver not included V BOX connect to Energy Meter N 3 Insert the neutral wire from the V BOX into the no 4 port at the bottom of the energy meter Flip open the bottom compartment and tighten the screw no 1 port top view 2 1 no 4 port bottom view 3 4 ...

Page 7: ...top of the energy meter Tighten the screw and close the compartment 5 Insert the live wire from the V BOX into the no 3 port at the bottom of the energy meter Tighten the screw and close the compartment V BOX connect to Energy Meter L no 3 port bottom view 3 4 no 2 port top view 2 1 ...

Page 8: ...s the enter button to select the function Scrolling Between Functions Scroll Buttons 1 total kWh 2 import kWh 3 export kWh 4 resettable kWh 5 total kVArh 6 import kVArh 7 export kVArh 8 resettable kVArh 9 max power demand 10 voltage 11 current 12 W watt 13 VAr volts amps reactive 14 VA volt ampere 15 power factor 16 frequency 17 DI 1 digital input 18 DI 2 19 modbus ID 20 baud rate 21 continuous ru...

Page 9: ...Page 8 total active energy 1 Function Description Order Display example 2 import active energy export active energy 3 total resettable energy 4 ...

Page 10: ...Page 9 total reactive energy 5 import reactive energy 6 export reactive energy 7 total resettable reactive energy 8 total max power demand 9 ...

Page 11: ...Page 10 voltage 10 current 11 active power 12 reactive power 13 apparent power 14 ...

Page 12: ...Page 11 power factor 15 frequency 16 DI 1 counting 17 DI 2 counting 18 modbus address 19 ...

Page 13: ...al 21 Setup Mode 1 Password You will first be asked to enter a password The Default password is 1000 Value Description Order Display example To go into setup mode and adjust the settings of your energy meter press and hold the enter button for 3 seconds ...

Page 14: ... the red digit will flash Press the scroll button to change the value Then press and hold the enter button to confirm 2 1 Baud rate Default value 2400bps Range 1200 2400 4800 9600 19200 bps 3 2 Address ID Default ID is 001 Range 001 247 ...

Page 15: ... button to change the value Then press and hold the enter button to confirm 3 1 Parity Default None Option None Even Odd 4 Press the enter button and the red digit will flash Press the scroll button to change the parity option Then press and hold the enter button to confirm 4 1 ...

Page 16: ...ss the scroll button to change the DIT option Then press and hold the enter button to confirm 5 1 Automatic Scroll Time Interval Default 0 seconds Option 0 30 sec 6 Demand Integration Time Default 15 minutes Option OFF 5 10 15 30 60 min energy consumption period 5 ...

Page 17: ...ton to adjust backlight duration 7 Press the scroll butto to change the backlight duration Then press and hold the enter button to confirm 7 1 Press the enter button and the red digit will flash Press the scroll button to change the time interval option Then press and hold the enter button to confirm 6 1 ...

Page 18: ...l button to go into the energy reset page Then press and hold the enter button to confirm 8 2 To clear the max demand of active power press and hold the enter button 8 1 Password Default 1000 9 Clear Press and hold the enter button to clear the interface 8 ...

Page 19: ...change the value After selecting a new password press and hold the enter button to confirm 9 1 DI filtering time Default 100 mS 10 Press the enter button and the red digit will flash Press the scroll button to change the value After selecting a new filtering time press and hold the enter button to confirm 10 1 ...

Page 20: ...Maximum current Display Maximum reading Power consumption Operating temp Weatherproof rating Dimensions Certification 100 240 V AC 50 60 Hz 10 10 A 100 A LCD with white backlight 999999 9 kWh kVArh 2W 10VA 13 ºF to 158 ºF IP51 indoor 14 2 x 39 x 25 in UL94 ...

Page 21: ...Scan the QR code below or email us at contact ev lectron com Get More Support www ev lectron com Made in China ...