Troubleshooting

Please refer to this troubleshooting guide for possible solutions to common problems 
while charging. 

Problem

Possible Cause

Solution

Mobile connector display 
does not illuminate.

No power to the mobile 
connector.

1. Check the circuit breaker and other circuit loads.
2. Try another wall outlet.
3. Ensure that the plug is fully inserted into the wall outlet.

Mobile connector internal failure.

Contact Lectron customer support at
contact@ev-lectron.com for assistance.

Vehicle will not charge.

Fault indicator remains
solid.

The handle is not fully inserted into the 
vehicle.

1. Inspect the handle.
2. Remove the handle from the vehicle, then fully reinsert it 
into your EV charging port.

Vehicle is not in a state to accept any 
charge.

Verify that the vehicle charge timer is set to permit 
charging. Refer to the vehicle owner’s manual for charge 
timer instructions.

Communication error between the 
charger and vehicle.

Fault indicator - on the 
mobile connector display -  
is blinking rapidly.

Utility fault.

1. Unplug from the wall outlet, then reconnect it.
2. If the problem persists, have a qualified electrician inspect 
the ground circuit of the wall outlet.

Above the temperature limit.

1. Temperature is too high. The 
mobile connector will restart charging 
when it cools down.

2. Wall outlet / wiring may be faulty.

1. Inspect the mobile connector for overheating.

2. Unplug it from the wall outlet.
3. Have a qualified electrician inspect the wall outlet and 
the mobile connector.

a. Carefully unplug from the wall outlet and allow 
it to cool.
b. If the problem persists, contact Lectron 
customer support at contact@ev-lectron.com for 
assistance.

Contact Lectron customer support at
contact@ev-lectron.com for assistance.

Summary of Contents for Level 1 EV Charger for J1772

Page 1: ...Level 1 Level 2 EV Charger for J1772 USER MANUAL ...

Page 2: ...rounded If it should malfunction or break down grounding provides a path of least resistance for electric current to help reduce the risk of elec tric shock This product includes a cord that is equipped with a grounding conduc tor and a grounding plug The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinanc es DO N...

Page 3: ... plug is fully inserted into the wall outlet so that there are no exposed blade surfaces Children should be supervised when in the vicinity of the charger while it is plugged in To reduce the risk of fire connect only to a circuit providing 20A 40A maximum branch circuit overcurrent protection Connecting the Plugs to Mobile Connector Select the appropriate plug 5 15 or 14 50 for your wall outlet 5...

Page 4: ...n the mobile connector display will show 3 LED lights and a blinking ring indicating that it is ready to charge your EV Ensure that the car is parked and the engine is turned OFF Note Find all charging statuses on the back of the mobile connector Slow blinking LED ring Continuous LED lights ...

Page 5: ...ging begins automatically The 3 LEDs will start blinking and the LED ring will light up Always double check your EV dashboard to make sure it is being charged Note Find all charging statuses on the back of the mobile connector Blinking LED lights Continuous LED ring ...

Page 6: ...rged the 3 LEDs will blink and the outer ring will stay solid Double check your EV dashboard to make sure it is fully charged 6 Remove the handle from your vehicle Fully Charged 210 V 6 6 A 0 km Slow blinking LED lights Continuous LED ring ...

Page 7: ...hat the vehicle charge timer is set to permit charging Refer to the vehicle owner s manual for charge timer instructions Communication error between the charger and vehicle Fault indicator on the mobile connector display is blinking rapidly Utility fault 1 Unplug from the wall outlet then reconnect it 2 If the problem persists have a qualified electrician inspect the ground circuit of the wall out...

Page 8: ...ellow Yellow Mobile connector back All of the charging statuses can be found on the back of the mobile connector Green L1 L2 L3 Ununited Connected Charging Charge Complete Communication Error Overcurrent Protection Overcurrent Protection Relay Failure Overvoltage and Undervoltage Protection Overheating Protection Grounding Abnormal Light Marquee Blink one time Light 0 5s Dark 1 5S Blink two times ...

Page 9: ...ble Length 21 ft 6 4 m Plug NEMA 5 15 14 50 EV connector Compatible with J1772 Dimensions 9 45 x 3 5 x 2 4 in Weight 4 5 kg Operating Temp 22 F to 122 F 30 C to 50 C Scan the QR code to contact us or send us an email at contact ev lectron com For more information visit www ev lectron com Made in China ...

Reviews: