LECTROSONICS, INC.
10
Setup Screen Details
Locking/Unlocking Changes to Settings
Changes to the settings can be locked in the Power Button Menu.
Locked?
No
Yes
LOCKED
(menu to
unlock)
Clock
Locked
LED Off
About
When changes are locked, several controls and actions can still be used:
• Settings can still be unlocked
• Menus can still be browsed
• When locked,
POWER CAN ONLY BE TURNED OFF by removing the
batteries.
Main Window Indicators
The Main Window displays the band number, Standby or Operating mode,
operating frequency, audio level, battery status and programmable switch
function. When the frequency step size is set at 100 kHz, the LCD will look
like the following.
474.500
-40
-20
0
b 470
2C
Block number
Frequency (MHz)
Frequency
(hex number)
Operating mode
Battery status
Audio level
When the frequency step size is set to 25 kHz, the hex number will appear
smaller and may include a fraction.
474.525
-40
-20
0
b 470
1
4
2C
Note that the
frequency has
increased by 25
kHz from the upper
example.
Fraction
1/4 = .025 MHz
1/2 = .050 MHz
3/4 = .075 MHz
Summary of Contents for SMWB series