BA SPOTLED II Einbau

 2  |  For safe operation

The operating parameters of the LED luminaire specified on the type plate must correspond to the supply parameters of 

the machine or of the switched-mode power supply.
Operate the luminaire only in a mounted status.

Under no circumstances may the luminaire be covered with cloths, foils or similar. Object 

distance the light-emitting surface should be at least 10 cm.
Machines can emit voltage spikes due to various factors. These voltage spikes in the 

power supply via machines should be avoided: Only use regulated 24V DC switched-mode 

power supplies, not transformers with rectifiers, as these can give rise to voltage spikes 

due to inductance.
Hot plugging should be avoided (connection of the luminaire to a power supply which is 

already connected to the mains), since this can lead to the destruction of  the LED luminaire.
LED luminaires react sensitively to high voltage transients if the necessary PSU are 

incorrectly selected. Choose a power supply solution that is adapted to your interference 

environment.
Luminaires without grounding and with conductive housing supplied via safety extra low 

voltage (SELV – protection class III), smallest discharge currents may occur when contact 

is made. According to DIN VDE 0701 – 0702, this discharge current must be limited to a 

maximum of 0.5 mA. All corresponding products from LED2WORK GmbH fall significantly 

below this specification.

 3  |  Safety information

Installation of electrical equipment may only be carried out by qualified electricians.  

Follow the five safety rules according to DIN VDE 1005. 

Failure to do so may result 

in damage to the LED luminaire, as well as fire or other hazards.

Danger of electric shock!

Disconnect before working on the device or load. Ensure to disconnect all circuit breakers 

that supply dangerous voltages to the device or load, when doing so. Even when the 

device is switched off, the load is not galvanically isolated from the mains.
Only use the device if it is completely free of faults, and with safety and awareness in 

mind.  If warnings or symbols are attached to the luminaire, they must not be removed.

 4  |  Assembly / Mounting

Check the LED luminaire before installation to ensure it is complete and shows no signs of damage. Do not use the 

luminaire or accessories if they are damaged, as there is a risk of injury.

The LED luminaire comes fully assembled. The LED Luminaire is for installation in a vertical installation bay (Dimensions 

of the luminaires in the drawings).

When mounting the luminaire, make sure that the luminaire is fastened securely and 

stably. If the luminaire falls down, its weight poses a risk of injury!

Summary of Contents for 111111-12

Page 1: ...MACHINES ILUMINACI N DE M QUINAS ILLUMINAZIONE MACCHINA Betriebsanleitung LED Einbauleuchte Operating Instructions LED recessed luminaire Manuel d utilisation Luminaire encastr LED Manual de instrucc...

Page 2: ...orbehalten Errors and technical changes excepted Sous r serve d erreurs et de modifications Sujeto a cambios y errores Tutte le modifiche o eventuali errori riservati Zeichnungen Drawings Sch mas Dibu...

Page 3: ...ter Verletzung f hren kann zeigt eine potenziell gef hrliche Situation an die wenn nicht vermieden zu geringf giger oder leichter Verletzung f hren kann zeigt eine potenziell gef hrliche Situation an...

Page 4: ...einer SELV Versorgung Schutz klasse III kann es bei Ber hrung zu geringen Ableitstr men kommen Dieser Strom ist laut DIN VDE 0701 0702 auf maximal 0 5 mA zu begrenzen Alle entsprechenden Produkte der...

Page 5: ...n Informationen zur Montage Die Leuchte darf nicht ge ffnet werden Die in der Leuchte montierten LED Lichtquellen sind in spezieller Weise mit dem Leuchtengeh use verbunden ther mische Kopplung und re...

Page 6: ...chmangel so tr gt er die Beweislast daf r dass das Ger t bereits bei Erhalt der Ware mangelhaft war Die Gew hrleistung bezieht sich nicht auf solche M ngel die durch Abnutzung fahrl ssi gen Gebrauch o...

Page 7: ...fung DIN EN 62471 Lichtfarbe 5200 5700K Farbwiedergabe Ra 80 LED Leuchte Art Nr Optik Stromst rke max Leistungsaufn max SPOTLED II Einbau 111111 12 16 0 35 A 8 5 W SPOTLED II Einbau 111112 12 25 0 35...

Page 8: ...avoided will result in death or serious injury Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation whi...

Page 9: ...ts may occur when contact is made According to DIN VDE 0701 0702 this discharge current must be limited to a maximum of 0 5 mA All corresponding products from LED2WORK GmbH fall significantly below th...

Page 10: ...ines or systems 6 Maintenance and Care The LED luminaire is maintenance free Do not make any alterations to the luminaire except according to the mounting information contained in this manual Do not o...

Page 11: ...strate that the product was already defective upon receipt The warranty does not extend to defects caused by wear negligence or improper use Further claims in particular claims for compensation for da...

Page 12: ...ture 10 40 C SPOTLED II V4A 30 40 C System of protection IP67 Technical safety inspection DIN EN 62471 Light colour 5200 5700K Colour rendering Ra 80 LED luminaire Product no Optics Max current Max po...

Page 13: ...ssible Les couleurs et les diff rentes nuances de gris ainsi que les symboles triangulaires soulignent visuellement le niveau de risque indique une situation de danger imm diat qui si elle n est pas v...

Page 14: ...nt des alimentations d coupage 24V DC r gul es et non des transformateurs redresseur dans la mesure o ceux ci peuvent d livrer des pics de tension en raison d inductances Le hot plugging connexion du...

Page 15: ...du luminaire repr sente un risque de blessure 5 Raccordement Vous trouverez le mat riel de raccordement les c bles et les accessoires appropri s dans l offre d accessoires de LED2WORK Le brochage du...

Page 16: ...n est accord e en cas de dommages caus s par l utilisation de d ter gents inappropri s 7 Garantie Nous accordons une garantie int grale pour cet appareil pendant 36 mois compter de la date d achat Cet...

Page 17: ...technique de s curit DIN EN 62471 Couleur de la lumi re 5200 5700K Rendu des couleurs Ra 80 Luminaire LED N d art Optique Intensit max Puissance absorb e max SPOTLED II Einbau 111111 12 16 0 35 A 8 5...

Page 18: ...la muerte o lesiones muy graves Indica una situaci n potencialmente peligrosa que de no evitarse puede provocar la muerte o lesiones muy graves Indica una situaci n potencialmente peligrosa que de no...

Page 19: ...entrar en contacto Esta corriente se debe limitar a 0 5 mA como m ximo conforme a la norma DIN VDE 0701 0702 Todos los productos correspondientes de LED2WORK GmbH quedan muy por debajo de esta especi...

Page 20: ...plantas 6 Mantenimiento y cuidado La luminaria LED no requiere mantenimiento No realices modificaciones excepto las que se indican en este manual de instrucciones para el montaje No se debe abrir la l...

Page 21: ...en el momento de recibirlo La garant a no cubre los defectos que se produzcan por el desgaste un uso negligente o un uso no previsto Quedan excluidas las reclamaciones particularmente las de compensa...

Page 22: ...SPOTLED II V4A 30 40 C Grado de protecci n IP67 Prueba de seguridad t cnica DIN EN 62471 Color de la luz 5200 5700K Representaci n de los colores Ra 80 Luminaria LED N de art culo ptica Intensidad de...

Page 23: ...re letale o comportare gravi lesioni segnala una situazione potenzialmente pericolosa che se non evitata pu comportare lesioni minime o di lieve entit segnala una situazione potenzialmente pericolosa...

Page 24: ...i collegamento a terra e con corpo conduttivo con alimen tazione SELV classe di isolamento III in caso di contatto potrebbero verificarsi esigue correnti di dispersione Tale corrente va limitata secon...

Page 25: ...ifiche alla lampada fatta eccezione per le informazioni relative al montaggio delle presenti istruzioni per l uso vietato aprire la lampada I LED presenti all interno della lampada sono collegati al c...

Page 26: ...materiale lavorazione o progettazione Qualora segnali un vizio mate riale l acquirente soggetto all onere di prova circa il sussistere del vizio gi al momento del ricevimento della merce La garanzia...

Page 27: ...62471 Colore della luce 5200 5700K Resa dei colori Ra 80 Lampada a LED Articolo no Ottica Intensit di corrente max Assorbimento potenza max SPOTLED II Aufbau 111111 11 16 0 35 A 8 5 W SPOTLED II Aufb...

Page 28: ...sich bei 2941 1660 00 LE d40 um eine Lichtquelle der Energieeffizienzklasse F 2941 1660 00 LE d40 is a light source with energy efficiency class F La d signation 2941 1660 00 LE d40 correspond une so...

Page 29: ...29 www led2work com shop led2work com BA SPOTLED II Einbau...

Page 30: ...uttgarter Str 13 A 75179 Pforzheim Germany T 49 7231 44920 00 info led2work com www led2work com LED2WORK GmbH BA 04 2022 BA SPOTLED II Einbau Irrt mer und nderungen vorbehalten Errors and technical c...

Reviews: