General instructions and regulations
Installation
• To secure the warranty, the Disk must be installed by a properly qualified person employed by
a dealer recognized by Harrie Leenders Haardkachels. See leenders.nl for a current list of
addresses of recognized dealers or contact the manufacturer.
• The stove is susceptible to scratching. Handle with care.
• After installation, check the draught by burning some kindling wood.
Use
• All local regulations including those referring to national and European standards must be
observed when installing the appliance.
• Ensure there is sufficient ventilation/air supply in the room where the stove is installed.
Air extractors such as a cooker hood may cause problems due to flue gases escaping from the
stove into the room.
• The appliance is not suitable for a shared flue system.
• The appliance must be installed on a floor having sufficient bearing capacity.
• Ensure adequate access for cleaning the appliance, the flue-gas connection and the chimney.
Safety instructions
• Glass is quite susceptible to breaking and broken glass is quite sharp. Take appropriate measures.
• For general safety, we refer to the VCA guidelines.
• Note: After installation, ensure there is no inflammable and/or explosion-hazardous material in or
on the stove such as a spray can, packing material and the like.
Distance to combustible materials
• Back:
150 mm
• Side:
250 mm
• Front:
1000 mm
Specifications Disk
• Nominal power = 4.9 kWh
• Flue gas mass flow = 4.1 g/s
• Appliance weight = 220 kg
• Minimum chimney draught = 0,12 mbar
• Flue gas temperature directly over the stove = 217 °C
• Energy Efficiency 84.4%, class A+, index 113,4
A
+