LOBBE
HARRIE LEENDERS
General instructions and regulations
Installation
•To secure the warranty, the Lobbe must be installed by a properly qualified person employed by a
dealer recognized by Harrie Leenders Haardkachels. See leenders.nl for a current list of addresses of
recognized dealers or contact the manufacturer.
•The stove is susceptible to scratching. Handle with care.
•After installation, check the draught by burning some kindling wood.
Use
•All local regulations including those referring to national and European standards must be observed
when installing the appliance.
•Ensure there is sufficient ventilation/air supply in the room where the stove is installed. Air extractors
such as a cooker hood may cause problems due to flue gases escaping from the stove into the room.
•The appliance is not suitable for a shared flue system.
•The appliance must be installed on a floor having sufficient bearing capacity.
•Ensure adequate access for cleaning the appliance, the flue-gas connection and the chimney.
Safety instructions
•Glass is quite susceptible to breaking and broken glass is quite sharp. Take appropriate measures.
•For general safety, we refer to the VCA guidelines.
•Note: After installation, ensure there is no inflammable and/or explosion-hazardous material in or on
the stove such as a spray can, packing material and the like.
Distance to combustible materials
Back: 200 mm
Side: 350 mm
Front: 1200 mm
Specifications Lobbe
•Nominal power = 5.2 kWh
•Flue gas mass flow = 5.8 g/s
•Appliance weight = 125 kg
•Minimum chimney draught = 11.9 Pa
•Flue gas temperature directly over the stove = 211 °C