background image

10 

 

c)

 

Clean the surface of the door with 
isopropyl alcohol and either air dry or dry 
with a clean cloth. 
 

d)

 

Heating the surface of the door 
immediately before applying the decal will 
aid the adhesive bond of the decal. Never 
apply a decal to a surface that is colder 
than 50° F. 

 

e)

 

Use a soft roller or plastic squeegee to 
apply the decal and press it into the 
embossed surface of the metal. Applying a 
small amount of heat to the surface of the 
decal will aid in this process. 
 

Door Gaskets and Hardware

:

 Routine 

inspection of the door gasket seal and the action 
of the door’s hinges are recommended. If damage 
has occurred to the gasket, it may allow outside 
air to penetrate the cabinet and the gasket should 
be replaced. The upright solid door utilizes the 
same hinge as the glass door. Leer solid doors 
have a barbed dart that inserts into a slot opening 
in the surface of the door frame. See 

Figure 3

 for 

instructions on solid door gasket replacement.                              

R290 Refrigeration Service: 

  Danger: Do not attempt to open the 

refrigeration system! Propane is a flammable 
and explosive gas.  

 
Like other refrigeration systems, a unit charged 
with R290 is not serviceable on a consumer level. 
Experienced technicians can contact Leer for an 
in-depth service and guideline manual. The use of 
special tools and proper procedures performed by 
licensed, trained and qualified professionals is 
required.   
 

R290 General Information

R290 refrigerant is flammable, but the amount of 
refrigerant used is relatively small and the chance 
of ignition in the event of refrigerant leak is 
extremely low. Millions of commercial and 
residential refrigeration products are already using 
similar, if not exact, refrigerants worldwide. 

R290 refrigeration grade propane has a much 
higher purity than standard propane. The higher 
moisture content of standard propane will damage 
a refrigeration system. Standard propane also has 
a scent added (another impurity) that refrigeration 
grade materials do not.  
 
R290 is a high-performance refrigerant. The 
superior thermodynamic properties of R290 
compared to R404a and R134a allow for a 
reduced charge per system and lower system 
energy use. 
 
Most important, It’s eco-friendly! R290 is 
classified as a hydrocarbon (HC) refrigerant, 
which is a natural, non-toxic, refrigerant and the 
top alternative to hydrofluorocarbon (HFC) 
refrigerants. R290 has an Ozone Depletion 
Potential (ODP) of 0 and an ultra-low Global 
Warming Potential (GWP) of 3.  

 

Summary of Contents for R290 PL

Page 1: ...800 766 5337 www leerinc com R290 PL and TD MERCHANDISER INSTALLATION OPERATION AND SERVICE MANUAL WARNING This product can expose you to chemicals including nickel which is known to the State of Cal...

Page 2: ...r manual owner s guide before attempting to service this product All safety precautions must be followed CAUTION Risk of fire or explosion Dispose of properly in accordance with federal or local regul...

Page 3: ...d Alarm Codes 6 Loading Ice 7 Maintenance and Service 7 Cleaning the Merchandiser 7 Cleaning Door Gaskets 7 Cleaning Condenser Coils 8 Defrosting the Merchandiser 8 Auto Defrost Electronic Control 8 G...

Page 4: ...iser installation location should have a solid level base If the merchandiser is exhibiting a slight forward lean the front of the cabinet should be blocked to bring the cabinet to a level position A...

Page 5: ...vaporator Indoor auto defrost models are supplied with a condensate evaporator heater assembly which is packaged and shipped inside the merchandiser It will require simple installation by the consumer...

Page 6: ...and contains two thermal couple probe wires Both probe wires are routed through the cabinet s suction line hole and into the unit cooler assembly which is mounted to the interior ceiling of the cabine...

Page 7: ...a flammable and explosive gas Component parts shall only be replaced with like components Maintenance and repair of the electrical and refrigeration systems should only be done by licensed trained and...

Page 8: ...consumer needs to install the condensate evaporator heater assembly described in the Installation section of this manual onto the exterior back wall of the cabinet The melt water from the defrost cyc...

Page 9: ...uce stretching If the door gasket appears to be in good condition but is failing to seal to the surface of the cabinet both the spring load tension and adjustment of the hinges should be checked Solid...

Page 10: ...nit charged with R290 is not serviceable on a consumer level Experienced technicians can contact Leer for an in depth service and guideline manual The use of special tools and proper procedures perfor...

Page 11: ...pring and place the Adjustment Collar over the round pin Fig 2 4 Using the Adjustment Pin turn the Adjustment Collar until the Pin contacts the Hinge Then insert the Stop Pin in hole of Adjustment Col...

Page 12: ...s to interfere with the new gasket installation 4 Align new gasket with door corners and use thumb to press into frame 5 Start at one corner of the frame and begin pressing the new gasket into the slo...

Page 13: ...d in compliance to UL Standard 471 Replacement parts that are not UL Certified or are not identical to the OEM installed part will void the merchandiser s UL Listing and or the Factory warranty Contac...

Page 14: ...cated below the threshold of the pallet load Connect each ramp by the grove and stud Repeat this process for ramp 3 Repeat for ramp 4 Move the ice into the Pallet Load Set the ice into place and remov...

Page 15: ...a pallet jack by the base pallet Move the box into place firmly against the aluminum back stop Lower the pallet jack and remove the base pallet The unit has a rubber gasket that will seal the unit fro...

Page 16: ...for repair or replacement of any defective part s or assembly only for defects reported to Seller within ninety 90 days after the date of installation ALL LABOR CHARGES SHALL BE AUTHORIZED OR APPROVE...

Reviews: