12
Solid Door Magnetic Gasket Replacement Instructions:
1.
Position solid door on a flat non-abrasive surface, exterior side down.
2.
Remove old gasket by grasping firmly at the corner and pulling away from the door frame extrusion.
3.
Inspect the extruded slot to insure there are no particles to interfere with the new gasket installation.
4.
Align new gasket with door corners and use thumb to press into frame.
5.
Start at one corner of the frame and begin pressing the new gasket into the slot. Using a non abrasive
tool such as a hammer head works well for this application. Apply downward pressure while moving
along the permeter of the frame. Excessive pressure may strech the gasket and cause bulging at the
corners.
Gasket Detail View Step 4
Step 5
Figure 3: Door Gasket Install