56
Commissioning
Code
Possible Settings
IMPORTANT
No.
Name
Default Selection
Segment #15
P780
Segment #15
Frequency
Setpoint
0.0
-500.0
{Hz}
500.0
If P112 = 1, negative sign forces
reverse direction
P781
Segment #15
Accel/Decel Time
20.0
0.0
{sec} 3600.0
P782
Segment #15
Time in current
step
0.0
0
0.0
{P708}
6553.5
0
{P708}
65535
Scaling/units depend on P708
Skip segment if time = 0
P783
Segment #15
Digital Output
State
0
Bit0 Relay
bit = 0: OFF (De-energized)
bit = 1: ON (Energized)
The corresponding digital output/
relay must be set to accept value the
from the sequencer: P140, P142=27
Bit1 TB14
P784
Segment #15
TB30
Analog Output
Value
0.00
0.00
{VDC} 10.00
TB30 configuration parameter must
be set to accept this value: P150
= 10
Segment #16
P785
Segment #16
Frequency
Setpoint
0.0
-500.0
{Hz}
500.0
If P112 = 1, negative sign forces
reverse direction
P786
Segment #16
Accel/Decel Time
20.0
0.0
{sec} 3600.0
P787
Segment #16
Time in current
step
0.0
0
0.0
{P708}
6553.5
0
{P708}
65535
Scaling/units depend on P708
Skip segment if time = 0
P788
Segment #16
Digital Output
State
0
Bit0 Relay
bit = 0: OFF (De-energized)
bit = 1: ON (Energized)
The corresponding digital output/
relay must be set to accept value the
from the sequencer: P140, P142=27
Bit1 TB14
P789
Segment #16
TB30
Analog Output
Value
0.00
0.00
{VDC} 10.00
TB30 configuration parameter must
be set to accept this value: P150
= 10
End Segment
P790
End Segment:
Frequency
Setpoint
0.0
-500.0
{Hz}
500.0
If P112 = 1, negative sign forces
reverse direction
P791
End Segment:
Accel/Decel Time
5.0
0.0
{sec} 3600.0
P792
End Segment:
Delay before
P793, 794 & 795
activation
0.0
{P708}
6553.5
0
{P708}
65535
Scaling/units depend on P708