3.2 Teach in handheld transceiver 

 
If a new or supplementary handheld transceiver shall be used, it has to be teached into the receivers memory. 
 
By pressing the push button “LEARN” while the receiver is in its normal operation mode, the device will change into a 
learn mode. This is displayed by an on state of the LED “LEARN/FUNCTION”.  
Now the lock function may be activated at the handheld transmitter which one shall work together with the receiver. 
After having learned the transmitters address, the receivers LED “LEARN/FUNCTION” switches off. 
 
A maximum of 8 different handheld transceiver addresses may be learned by each receiver. So, if you try to teach in the 
9

th

 address, the LED “LEARN/FUNCTION” flashes slowly 3 times to signalise the non accepted new device. 

 
In this case all learned addresses must be erased. Therefore press the push button “LEARN” once, as you do for 
entering into the learn mode and then press again and hold the same pushbutton for at least 5 seconds. 
The learn mode will then be left automatically. 
 
If the learn mode has been activated accidentally without teaching in a transmitter, it will be left automatically after 30 
seconds. 

 

 

3.3 Technical details 

 

Frequency: 

 

one of the frequency channels is automatically selected, depending on the transmitters 

frequency 

 

 

 

channel 1: 910.000 MHz  

 

 

 

channel 2: 910.300 MHz 

 

 

 

channel 3: 910.600 MHz 

 

 

 

channel 4: 910.900 MHz 

Dimension:  

 

255mm x 180mm x 95mm 

Supply:  

 

24V DC, 

without reverse polarity protection!

 

Limit switch inputs: 

18,5V to 28V (high active) with LED display at each input 

 

 

Summary of Contents for SH-12

Page 1: ...protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interferenc...

Page 2: ...played by the 6 blue LEDs and the green LED stops flashing if the lock function is completed If lock or unlock function is activated but not yet completed both of them may be interrupted at any time by pressing push button 4 STOP This results in stopping all motor outputs at receivers side While the stop command is transmitted to the receiver the red and the green LED will flash as long as the sig...

Page 3: ...ted frequency channel is stored The receiver needs not to be changed It will automatically synchronize to the selected transmitter frequency 2 3 Technical Details Frequency channel 1 910 000 MHz factory setting channel 2 910 300 MHz channel 3 910 600 MHz channel 4 910 900 MHz Supply 4 5 V DC 3 alkaline batteries type AAA Dimension 120x70x30mm Manipulation 4 push buttons 2 x ENABLE within 0 5 s ena...

Page 4: ...e number of usable motor driver outputs and limit switch inputs is factory predifined The lock function is analogous to the unlock funtion Only LEDs and outputs are labeled V Motor driver outputs giving the positiv voltage are displayed by the LEDs placed above display motor driver All start up features for motor driver and the reaction when motors are blocked are factory settings and may not be c...

Page 5: ...h address the LED LEARN FUNCTION flashes slowly 3 times to signalise the non accepted new device In this case all learned addresses must be erased Therefore press the push button LEARN once as you do for entering into the learn mode and then press again and hold the same pushbutton for at least 5 seconds The learn mode will then be left automatically If the learn mode has been activated accidental...

Reviews: