INSTALLING YOUR UPS SYSTEM 

 

UNPACKING 

The box should contain the following: 
(1) UPS unit ; (1) User’s manual for UPS; (1) SeeUPS2020 software; (1) serial interface cable (DB-9);  
(1) Telephone communication cable; (1) warranty registration card. 

 

HARDWARE INSTALLATION GUIDE 

 

1.  Your UPS may be used immediately upon receipt.  However, 

recharging the battery for at least 

four  hours

  is  recommended  to  insure  that  the  battery’s  maximum  charge  capacity  is  achieved.  

Charge  loss  may  occur  during  shipping  and  storage.    To  recharge  the  battery,  simply  leave  the 
unit plugged into an AC outlet.  The unit will charge in both the on as well as the off position. 

 
2.  If you wish to use the software, connect the  

enclosed serial interface cable to the serial port  
on the UPS and an open serial port on the  
computer.  If you are not going to use the  
software, you do not need to connect the cable. 

 

3.  With  the  UPS  unit  off  and  unplugged,  connect  your  computer,  monitor,  and  any  externally 

powered  data  storage  device  (Zip  drive,  Jazz  drive,  Tape  drive,  etc…)  into  the  battery  power 
supplied  outlets.    Plug  your  peripheral  equipment(printer,  scanner,  speakers)  into  the  full-time 
surge protection outlets.  

DO NOT  plug  a  laser  printer, copier, space  heater,  vacuum, 

paper 

shredder

  or  other  large  electrical  device  into  the  UPS.    The  power  demands  of  these 

devices will overload and possibly damage the unit. 

 

4.  To  protect  a  fax,  telephone,  modem  line  or  network  cable,  connect  a 

telephone cable or network cable from the wall jack outlet to the IN jack of 
the UPS. Then connect a telephone cable or network cable from the OUT 
jack  on  the  UPS  to  the  modem,  computer,  telephone,  fax  machine,  or 
network device. 

 
5.  Plug the UPS into a 2 pole, 3 wire grounding receptacle (wall outlet).  Make sure the wall branch 

outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical 
demands (e.g. refrigerator, copier, etc…).  Avoid using extension cords.   

 
6.  Depress the power switch to turn the unit on.  The power on indicator light will illuminate and the 

unit will “beep” once. 

 
7.  If  an overload is detected, an audible  alarm  will sound  and the unit  will emit  one long  beep.  To 

correct this, turn the UPS off and unplug at least one piece of equipment from the battery power 
supplied outlets.  Wait 10 seconds.  Make sure the circuit breaker is depressed and then turn the 
UPS on. 

 
8.  Your UPS is equipped with an auto-charge feature.  When the UPS is plugged into an AC outlet, 

the battery will automatically recharge. 

 
9.  To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 
 
10. To  store  your  UPS  for  an  extended  period,  cover  it  and  store  with  the  battery  fully  charged.  

Recharge the battery every three months to insure battery life. 

Summary of Contents for Legend SB500R

Page 1: ...User s Manual Legend SB500R UPS K01 1120008 00...

Page 2: ...CATIONS 7 LIMITED WARRANTY 8 Thank you for purchasing a Legacy Power Conversion Product To enjoy all the features and benefits of this Uninterruptible Power System UPS please read and follow all insta...

Page 3: ...t equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the risk of fire...

Page 4: ...large electrical device into the UPS The power demands of these devices will overload and possibly damage the unit 4 To protect a fax telephone modem line or network cable connect a telephone cable or...

Page 5: ...nated disconnect all electrical equipment from the outlet and have an electrician check to ensure the outlet is properly wired 5 Circuit Breaker Located on the side of the UPS the circuit breaker serv...

Page 6: ...ipment exceeds the rating of unit Turn the UPS off unplug at least one piece of equipment wait 10 seconds reset the circuit breaker and turn the unit on Off On Off Set Long Beep Battery Overload Occur...

Page 7: ...110 120v 60Hz outlet The battery is worn out Contact Legacy Power Conversion about replacement batteries at service lpc ups com or 800 859 5711 The UPS will not turn on Mechanical problem Contact Leg...

Page 8: ...RJ11 RJ45 One In One Out Operating Temperature 32 F to 95 F 0 C to 35 C Maximum Dimensions cm 1U Rack 43 1 x 24 7 x 4 4 Weight kg 5 3 Typical Battery Recharge Time 8 hours typical from total discharg...

Page 9: ...establish that you are the Initial Customer of the Product and therefore entitled coverage under the Limited Warranty Registration is not required for Limited Warranty coverage but note if you do not...

Page 10: ...nse or if Legacy is unable to or decides not to repair or replace the Product if defective within a reasonable time Legacy will refund to you the full purchase price you paid for the Product purchase...

Page 11: ...es even though damage or loss is caused by negligence or other fault NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitati...

Page 12: ...crease the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienc...

Reviews: