background image

 

 
 

FRONT AND REAR PANEL DESCRIPTIONS 

 

 
 

1.  Battery/Surge Outlets 

Provides  four  battery  powered/surge  outlets  for  connected  equipment  and  insures  temporary 
uninterrupted operation of your equipment during a power failure. 
 

2.  Power Switch 

Can be used as a mater on/off switch for equipment connected to the battery power supplied outlets. 
 

3.  Power On Indicator 

This LED is illuminated when the utility condition is normal and the UPS outlets are providing power, 
free of surges and spikes. 
 

4.  Electrical Wiring Fault Indicator 

This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, 
missed ground or reversed wiring.  If this is illuminated, disconnect all electrical equipment from the 
outlet and have an electrician check to ensure the outlet is properly wired. 
 

5.  Circuit Breaker 

Located  on  the  side  of  the  UPS,  the  circuit  breaker  serves  to  provide  overload  and  fault  protection.  
Under normal operating conditions, the circuit breaker is depressed. 
 

6.  Serial Port to PC 

This port allows connection and communication from the DB-9 serial port on the computer to the UPS 
unit.    The  UPS  communicates  its  status  to  the  PowerPanel™  software.    This  interface  is  also 
compatible with the UPS service provided by Windows NT Windows 2000, and Windows XP. 
 

7.  Communication Protection Ports 

Communication  protection  ports  will  protect  any  standard  modem,  fax  ,  telephone  line,  or  network 
cable. 
 

8.  Outlets Designed for AC Adapters 

Allows six AC power adapter blocks to be plugged into the UPS without blocking adjacent outlets. 

Summary of Contents for Legend SB500R

Page 1: ...User s Manual Legend SB500R UPS K01 1120008 00...

Page 2: ...CATIONS 7 LIMITED WARRANTY 8 Thank you for purchasing a Legacy Power Conversion Product To enjoy all the features and benefits of this Uninterruptible Power System UPS please read and follow all insta...

Page 3: ...t equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the risk of fire...

Page 4: ...large electrical device into the UPS The power demands of these devices will overload and possibly damage the unit 4 To protect a fax telephone modem line or network cable connect a telephone cable or...

Page 5: ...nated disconnect all electrical equipment from the outlet and have an electrician check to ensure the outlet is properly wired 5 Circuit Breaker Located on the side of the UPS the circuit breaker serv...

Page 6: ...ipment exceeds the rating of unit Turn the UPS off unplug at least one piece of equipment wait 10 seconds reset the circuit breaker and turn the unit on Off On Off Set Long Beep Battery Overload Occur...

Page 7: ...110 120v 60Hz outlet The battery is worn out Contact Legacy Power Conversion about replacement batteries at service lpc ups com or 800 859 5711 The UPS will not turn on Mechanical problem Contact Leg...

Page 8: ...RJ11 RJ45 One In One Out Operating Temperature 32 F to 95 F 0 C to 35 C Maximum Dimensions cm 1U Rack 43 1 x 24 7 x 4 4 Weight kg 5 3 Typical Battery Recharge Time 8 hours typical from total discharg...

Page 9: ...establish that you are the Initial Customer of the Product and therefore entitled coverage under the Limited Warranty Registration is not required for Limited Warranty coverage but note if you do not...

Page 10: ...nse or if Legacy is unable to or decides not to repair or replace the Product if defective within a reasonable time Legacy will refund to you the full purchase price you paid for the Product purchase...

Page 11: ...es even though damage or loss is caused by negligence or other fault NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitati...

Page 12: ...crease the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienc...