Legend SB500R 

Uninterruptible Power System 

 

5

 

 

 

 

DEFINITIONS FOR ILLUMINATED LED INDICATORS 

 

 

 

Power 

ON 

 

Wiring 

Fault 

 

Circuit 

Breaker 

 

Alarm 

CONDITION 

On 

Off 

Set 

Off 

Normal 

Off 

On/Off 

Set 

Two 

Beeps 

Utility Failure- 

the UPS is providing power to 

battery power-supplied outlets from its battery. 

Off 

On/Off 

Set 

Rapid 

Beeps 

Utility Failure-

 The UPS is providing battery 

power.  Rapid beeps indicate the unit will run 

out of power shortly. 

Off 

Off 

Up 

Two 

Beeps 

or          

Rapid 

Beeps 

 

System Overload- 

Occurs when connected 

equipment exceeds the rating of unit.  Turn the 

UPS off, unplug at least one piece of 

equipment, wait 10 seconds, reset the circuit 

breaker and turn the unit on. 

Off 

On/Off 

Set 

Long 
Beep 

Battery Overload-

 Occurs when connected 

equipment exceeds the rating of battery 

outlets of the unit.  Turn the UPS off, unplug at 

least one piece of equipment from battery 

outlets, wait 10 seconds, reset the circuit 

breaker and turn the unit on. 

On/Off 

On 

Set 

None 

Electrical Wiring Fault- 

This indicates a 

wiring problem with the AC outlet such as bad 

ground, missed ground, or reversed wiring.  

User is advised to disconnect all electrical 

equipment from the outlet and have an 

electrician check the outlet to insure proper 

wiring. 

 

Summary of Contents for Legend SB500R

Page 1: ...User s Manual Legend SB500R UPS K01 1120008 00...

Page 2: ...CATIONS 7 LIMITED WARRANTY 8 Thank you for purchasing a Legacy Power Conversion Product To enjoy all the features and benefits of this Uninterruptible Power System UPS please read and follow all insta...

Page 3: ...t equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the risk of fire...

Page 4: ...large electrical device into the UPS The power demands of these devices will overload and possibly damage the unit 4 To protect a fax telephone modem line or network cable connect a telephone cable or...

Page 5: ...nated disconnect all electrical equipment from the outlet and have an electrician check to ensure the outlet is properly wired 5 Circuit Breaker Located on the side of the UPS the circuit breaker serv...

Page 6: ...ipment exceeds the rating of unit Turn the UPS off unplug at least one piece of equipment wait 10 seconds reset the circuit breaker and turn the unit on Off On Off Set Long Beep Battery Overload Occur...

Page 7: ...110 120v 60Hz outlet The battery is worn out Contact Legacy Power Conversion about replacement batteries at service lpc ups com or 800 859 5711 The UPS will not turn on Mechanical problem Contact Leg...

Page 8: ...RJ11 RJ45 One In One Out Operating Temperature 32 F to 95 F 0 C to 35 C Maximum Dimensions cm 1U Rack 43 1 x 24 7 x 4 4 Weight kg 5 3 Typical Battery Recharge Time 8 hours typical from total discharg...

Page 9: ...establish that you are the Initial Customer of the Product and therefore entitled coverage under the Limited Warranty Registration is not required for Limited Warranty coverage but note if you do not...

Page 10: ...nse or if Legacy is unable to or decides not to repair or replace the Product if defective within a reasonable time Legacy will refund to you the full purchase price you paid for the Product purchase...

Page 11: ...es even though damage or loss is caused by negligence or other fault NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitati...

Page 12: ...crease the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienc...

Reviews: