1
DEFINITIONS FOR LED INDICATORS
8
Power
On
Wiring
Fault
AVR
Using
Battery
Circuit
Breaker
Alarm
Condition
On
Off
Off
Off
Set
Off
Normal
On
Off
Flash
Off
Set
Off
AVR-
Max. boost 15% of input
voltage for output regulation while
input voltage is from 8% to 30%
under nominal.
ON
Off
On
Off
Set
Off
AVR-
Max. buck 15% of input
voltage for output regulation while
input voltage is from 8% to 26%
over nominal.
Off
On/Off
Off
On
Set
Two
Beeps
Utility Failure-
The UPS is
providing battery power to the
Battery-Power Supplied outlets.
Off
On/Off
Off
On
Set
Rapid
Beeps
Utility Failure-
The UPS is
providing battery power. Rapid
beeps indicate the battery will run
out of charge within a few minutes.
On/Off On/Off
On/ Off
/Flash
On/Off
Set
Long
Beep
Overload-
Turn the UPS off and
unplug at least one piece of
equipment from the UPS. Wait 5
seconds, reset the circuit breaker
and restart the UPS.
Off
Off
Off
On
Up
Long
Beep
Overload-
Turn the UPS off and
unplug at least one piece of
equipment from the UPS. Wait 5
seconds, reset the circuit breaker
and restart the UPS.
On
On/Off
On/ Off
/Flash
Off
Set
None
Weak Battery-
Recharge the
battery for at least 8 hours. If
Check Battery
is illuminated,
contact Legacy Power Conversion
for battery replacement
information.
Off
Off
Off
Off
Set
Off
Surge Protection Malfunction-
Power surge has damaged the
unit. Please contact Legacy Power
Conversion
On/Off
On
On/ Off
/Flash
On/Off Set/Up None
Electrical Wiring Fault-
Indicates
wiring problems such as a bad
ground, missed ground or
reversed wiring
within the AC
outlet
. User is advised to
disconnect all electrical equipment
from the outlet and have the outlet
checked by an electrician.