5.3.Installing the Battery Pack

5.3.1.Mounting to a wall

WARNING

In order to avoid electrical shock or other injury, inspect existing electronic or plumbing installations before drilling holes.
The battery is heavy, please handle with care to avoid damage to the product or injury to the installer.

1.Choose suitable firm wall with thickness greater than 80mm.
2.Use the mounting frame as a template, mark the hole position.
3.Drill 8 holes according to the hole position, it is ø10 with depth 60mm.
4.Hammer the M8 screws to the above holes, and screw the nut. Note: Do not position screws flush to

the wall - leave 10 to 20 mm exposed.

5.Fix the mounting frame to the 8 screws.
6.Raise the battery a little higher than the mounting frame whilst maintaining the balance of the battery.

Hang the battery on the frame through the match hooks.

WARNING

Falling equipment can cause serious or even fatal injury: never mount the inverter on the bracket unless you are sure that

the mounting frame is firmly mounted on the wall after thorough checking.

5.4.Parallel use of battery

When the battery needs to be used in parallel, the maximum connection is 10units, but we recommend

to use 2-4 units according to application. The application needs power and communication connections

as below, choose suitable accessories:

Summary of Contents for 10KWH-A162

Page 1: ...USER MANUAL FOR WALL ENERGY LITHIUM STORAGE SYSTEM MODEL LEGACY 5KW 10KW VOLTAGE 48V 51 2V ...

Page 2: ...ndicator Guides 5 3 4 Connectors 6 3 5 Wake Up button 6 3 6 Display function instruction 6 4 Safe handling guide 8 4 2 Safety Gear 9 5 Installation 9 5 1 Inventory of items 9 5 2 Installation Location 9 5 3 Installing the Battery Pack 11 5 4 Parallel use of battery 11 6 Communication 12 6 1 Battery and PC communication note insert the RS232 port 12 6 2 How To Connect Inverter 13 7 Abnormal situati...

Page 3: ...ery and packing list first if the battery is damaged or spare parts are missing Please contact the dealer Before installation be sure to cut off the grid power and make sure the battery is in the turned off mode Wiring must be correct do not mix connect the positive and negative cables and ensure no short circuit with the external device It is prohibited to connect the battery with AC power direct...

Page 4: ...0 years Life cycles 80 DOD 25 C 6000Cycles Storage time temperature 5 months 25 C 3 months 35 C 1 month 45 C Operation temperature 20 C to 60 C 60 25 Relative Humidity Storage temperature 0 C to 45 C 60 25 Relative Humidity Lithium Battery Standard UN38 3 MSDS CE EMC IEC62619 cell UL1973 cell Enclosure protection rating IP50 Electrical Parameters Operation voltage 45 53 5 VDC 48 56VDC 45 53 5 VDC ...

Page 5: ...onitor battery information including voltage current and temperature as well as balance cell charging discharging rates 5 10 year warranty 3 2 Interface Introduction This section details the interface functions of front and back panel Front interface No Description Silk screen Remark 1 UES0600 P P Output terminal 2 UES0600 P P Output terminal 3 port Reset button RST For reset the batter 4 Dial swi...

Page 6: ...6 32 2 OFF OFF OFF OFF Flash ON OFF OFF OFF OFF NO NO 32 2 49 8 OFF OFF OFF Flash ON ON OFF OFF OFF NO NO NO 49 8 66 4 OFF OFF Flash ON ON ON OFF OFF NO NO NO NO 66 4 83 OFF Flash ON ON ON ON OFF NO NO NO NO NO 83 100 Flash ON ON ON ON ON NO NO NO NO NO NO RUN Status ON Flash Status Normal Warning Protection RUN ALM Capacity LED Description Shut Down Shut down OFF OFF OFF OFF OFF OFF OFF OFF All O...

Page 7: ...5 Wake Up button Switch on When battery is shut down press the ON OFF button for 3 seconds It is activated when the LED lights flicker from RUN light to the lowest capacity indicator Switch off When battery is activated press the ON OFF button for 3 seconds It will be shut down when the LED lights flicker from lowest capacity indicator to RUN light RESET Key Press RST key for 6 seconds reset BMS t...

Page 8: ... main menu page As shown in the figure below Battery parameters collection page When the cursor is point to Battery Parameters Acquisition press ENTER key will enter into the page of Battery Parameters Acquisition As shown in the figure below Battery status page When the cursor is point to Battery Status press ENTER key will enter into the page of Battery Status As shown in the figure below ...

Page 9: ... project the content of the said project has not shown press ENTER key can enter the corresponding page 3 Press ESC key can be returned at the next higher level directory In any position press NEMU key can return to the main menu page 4 In a dormant state press any key can activate the screen Dormancy shutdown Under normal operation condition with no keystrokes 1 minutes later system will enter a ...

Page 10: ...nsulated gloves Safety goggles Safety shoes 5 Installation 5 1 Inventory of items Thoroughly inspect the packaging upon receipt of goods If there is any item that is missing or if there is any damage to the external packaging or to the unit itself upon unpacking please contact Sapphire Solar immediately A B C D E NO Item Quantity Specification A Battery Pack 1 5KWH 10KWH B Mounting frame 1 SPCC C ...

Page 11: ...ion must be vertical or tilted backwards by maximum 15 avoid forward or sideway stilt CAUTION If the ambient temperature is outside the operating range the battery pack stops operating to protect itself The optimal temperature range for the battery pack to operate is 0 C to 45 C Frequent exposure to harsh temperatures may deteriorate the performance and life of the battery pack 5 2 1 Minimum clear...

Page 12: ...les and screw the nut Note Do not position screws flush to the wall leave 10 to 20 mm exposed 5 Fix the mounting frame to the 8 screws 6 Raise the battery a little higher than the mounting frame whilst maintaining the balance of the battery Hang the battery on the frame through the match hooks WARNING Falling equipment can cause serious or even fatal injury never mount the inverter on the bracket ...

Page 13: ...t line A C E G of the battery terminal and the negative output line B D F H of the battery terminal 8 The other end of the battery A C E G is connected to the leakage switch of the combiner box The negative B D F H is connected to the leakage switch of the combiner box 9 Connect J1 with inverter s negative pole 10 Connect J2 with inverter s positive pole 11 Add suitable isolators when necessary 6 ...

Page 14: ...6 2 1 The communication PIN of battery and the inverter Battery Pack Inverter Pin1 NC Pin1 NC Pin2 NC Pin2 NC Pin3 NC Pin3 NC Pin4 CANH Pin4 CANH Pin5 CANL Pin5 CANL Pin6 NC Pin6 NC Pin7 GND Pin7 GND Pin8 NC Pin8 NC 6 2 2 Dial settings of battery ADS address ...

Page 15: ...www connectinglegacy com 14 6 2 3 How to connect Deye inverter ONE SET OF BATTERY TWO SETS OF BATTERIES THREE SETS OF BATTERIES Four SETS OF BATTERIES ...

Page 16: ...www connectinglegacy com 15 6 2 3 1 The communication setting steps of the inverter 1 Click on Setting on the lcd 2 Click on Battery setting select Lithium as the battery mode ...

Page 17: ...Lithium mode select 00 4 After lithium mode connected successfully BMS will upload the data as below 6 2 4 How To Connect Growatt Inverter 6 2 4 1 Canbus communication setting of the inverter ONE SET OF BATTERY TWO SETS OF BATTERIES ...

Page 18: ...www connectinglegacy com 17 THREE SETS OF BATTERIES Four SETS OF BATTERIES 6 2 4 1 1 Can bus communication setting steps of the inverter 1 LCD setting as below ...

Page 19: ...www connectinglegacy com 18 2 Click on Battery setting select Lithium as battery mode 3 Click on Enter and Down Up to select 36 and L52 4 Click on ESC and wait till the connection done ...

Page 20: ...www connectinglegacy com 19 6 2 4 2 RS485 communication setting of the inverter ONE SET OF BATTERY TWO SETS OF BATTERIES THREE SETS OF BATTERIES Four SETS OF BATTERIES ...

Page 21: ...tinglegacy com 20 6 2 4 2 1 RS485 communication setting steps of the inverter 1 Lcd setting as below 2 Click on Enter and Down Up to select 05 and LI Lithium mode 3 Click on Enter and Down Up to select 36 and L04 ...

Page 22: ...he PC software used correctly Whether the PC software correctly reads the serial port Signal line wiring and address are correct Equipment overload Excessive power or short circuit Check if the load is less than the rated power of the device Confirm if there is a short circuit condition Battery failure Fault light red light is always on Press the SET button 6S all the indicators light up at the sa...

Page 23: ... information of this product please contact us 3 The shelf life of this product is within 5 10 Years after it is delivered we will maintain the product which is in the warranty period for free of charge provided that it has any product quality problems within the specified operation range we may replace the relevant parts if we fail to maintain it so as to achieve the purpose of sustainable use wi...

Reviews: