For best results, install out of direct sunlight, water or very damp air.
Power supply service must be installed within proximity of electric
fireplace prior to finishing avoiding reconstruction.
Minimum Clearance to Combustibles
Sides............................0 inch
Floor............................0 inch
Back.............................0 inch
Top (shelf or TV)..........8 inch min
Front...........................36 inch
WARNING! Risk of Fire!
Keep electrical cords, drapery, furnishings or
other combustibles at least 3ft. (0.9 m) from the front of the electric
fireplace.
Electrical Supply Circuit Requirements
Plan the location of the appliance so that it will have adequate electric
power. A 15AMP, 120V/60Hz circuit is required. Additional appliances on
the same circuit as this appliance may exceed the current rating of that
circuit. A dedicated circuit is not required, but is preferred to prevent
circuit breaker or fuse failure.
Prepare the outlet close to the right side of appliance. Make sure the
outlet is in good condition and the plug must be plugged tightly in the
outlet.
For hard wiring, please refer to page 17.
4a. Recessed into the wall
4a.1. Build the framing by 2x6” stud, below picture of 50” as an example.
Dimensions for all sizes are listed below. The appliance will be