background image

12

1111..00

TTR

RO

OU

UB

BLLEESSH

HO

OO

OTTIIN

NG

G G

GU

UIID

DEE

FFiirree ssppaarrkkss bbuutt ppiilloott ddooeess nnoott lliigghhtt

No gas to fire, check isolators are open. 
Pipe work blockage, clean out.  
Air not fully purged, re purge supply or wait longer.  
Spark earthing to metal work, reset gap correctly.
Blocked pilot, clean out internally.

PPiilloott lliigghhttss bbuutt tthheenn ggooeess oouutt

Severe restriction in gas supply: clear obstruction.  
Faulty thermocouple, replace pilot unit.  
Blocked pilot, clean out. 
Blocked lint gauze, clean. 
Hold control knob in for longer. 
Check control knob does not foul the control indicator plate.
If the pilot will not stay lit there is a problem with dirt, the gas sup-
ply, or the thermocouple needs replacement. Modifications are 
dangerous and can have a serious unseen effect on safety.
NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE 
PILOT STAY ALIGHT. 

FFiirree ddooeess nnoott ssppaarrkk aatt ppiilloott

HT lead detached, refit.  
Check the spark gap (see section 8.2).
Faulty piezo unit, replace.  
Debris shorting out electrode, clean.  
Spark shorting to metalwork under tray, realign HT lead.

FFiirree rruunnss ffoorr aa ttiim

mee aanndd tthheenn ccuuttss ooffff

Loose or faulty thermocouple, rectify. 
Blocked pilot, clean out. 
Dirt or lint in pilot aeration hole or on the lint gauze, clean 
thoroughly.
If the pilot will not stay lit there is a problem with dirt, the gas sup-
ply, or the thermocouple needs replacement. Modifications are 
dangerous and can have a serious unseen effect on safety.
NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE 
PILOT STAY ALIGHT. 

PPiilloott ffllaam

mee sshhrriinnkkss w

whheenn ffiirree iiss oonn hhiigghh

Poor gas flow to fire, check pressure with fire on high.  
If pressure is low, remove any restriction in pipework or valve.  
Check all isolators are adequately sized and fully open. 
Check meter pressure is adequate. 
If the pilot will not stay lit there is a problem with dirt, the gas sup-
ply, or the thermocouple needs replacement. Modifications are 
dangerous and can have a serious unseen effect on safety.
NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE 
PILOT STAY ALIGHT. 

FFiirree ssm

meellllss w

whheenn ffiirrsstt lliitt oorr iinn uussee

Newness smell from brand new appliance.  
Leakage occurring.  Carry out leakage test and rectify any problems.
Combustible materials used in incorrect positions.

1

Summary of Contents for ECO 1000

Page 1: ... the end user when the installation is complete This is an official requirement and is the responsibility of the fitter of this appliance Having installed the appliance the installer should take the necessary steps to ensure that the user fully understands how to operate the appliance and is also made aware of the fire s basic cleaning and maintenance requirements ...

Page 2: ...e circulation of air and ensure the correct operation of the fire This volume may include adjacent spaces but these spaces must not be separated by a door In order to convert from cubic feet ft3 to cubic metres m3 divide the room volume in ft3 by 35 3 This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background heating present The a...

Page 3: ...ace A minimum of 100cm2 15 5 in2 purpose provided ventilation is required for this appliance an openable window or louvre is also required To reduce the pos sibility of draughts entering the room via the air vent we recommend the use of Black Hole or Vortex type vents featuring internal baffles Consult ALL instructions before installation and use of this appliance This appliance is free from any a...

Page 4: ... r re ec ce es ss s a an ny y p pa ar rt t o of f t th he e a ap pp pl li ia an nc ce e i in nt to o t th he e w wa al ll l This Appliance may be installed in any room in a home however there are exceptions and the appliance may not be used in the following rooms Bedrooms or areas which are mainly used for sleeping Bathrooms or areas where large amounts of steam are likely to be generated Installa...

Page 5: ...e wall above the appliance The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire surround No combustible shelves should be positioned on the wall above the appli ance It should be established that any mirrors or picture frames etc to be positioned on the wall above the appliance are able to withstand prolonged exposure to moderate heat and mois...

Page 6: ...e firebox Select the most appropriate entry point and knock out the relevant holes in both the firebox and the outer casing No more than 1 5m of 8mm diameter pipe must be used to avoid unnecessary pressure drops If a concealed gas connection is to be made the supply pipe should always be sleeved through walls and floors using the shortest possible route For concealed supply pipe routing pipes must...

Page 7: ...l drill four holes using a 7mm masonry bit Insert the fibre wallplugs provided If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then special cavity screw fixings will be required which are not supplied with this product These should be constructed from metal and not plastic Insert the screws into the upper two holes leaving 5mm protruding from the wall Tem...

Page 8: ... the knob pressed in return to the off position and release S SP PA AR RK K F FA AI IL LU UR RE E The gap between the spark electrode and the pilot should be 3 5mm to produce a good spark There should be no need to adjust this If under any circumstances the piezo electric spark fails the pilot cannot be lit man ually S SE ET TT TI IN NG G P PR RE ES SS SU UR RE E To commission the appliance the bu...

Page 9: ...a guard be used for the protection of the young pets the eld erly and the infirm S SE ER RV VI IC CI IN NG G Isolate the fire from the gas supply Ensure that the fire is fully cold before attempting service A suggested pro cedure for servicing is detailed below 1 Lay out the dustsheet and tools 2 Remove the facia section Removal is the reverse of fitting as detailed in section 8 4 3 Remove the gla...

Page 10: ... not damage or try to dismantle the pilot injector The unit is factory set and the only check necessary is to ensure the spark gap is correct See specifications for gas setting N NE EV VE ER R M MO OD DI IF FY Y O OR R B BE EN ND D T TH HE E T TH HE ER RM MO OC CO OU UP PL LE E T TO O M MA AK KE E T TH HE E P PI IL LO OT T S ST TA AY Y A AL LI IG GH HT T If the pilot will not stay lit there is a p...

Page 11: ... removed be unscrewing the retaining nuts securing the clamping plate Remove the catalyst and its seal and discard Refit a new catalyst and seals in reverse order ensure the catalyst and door have good seals T TE ES ST TI IN NG G F FO OR R F FI IR RE EB BO OX X L LE EA AK KA AG GE E Appliances that are several years old or have been extensively dismantled should be checked for soundness It is impo...

Page 12: ...ing to metalwork under tray realign HT lead F Fi ir re e r ru un ns s f fo or r a a t ti im me e a an nd d t th he en n c cu ut ts s o of ff f Loose or faulty thermocouple rectify Blocked pilot clean out Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit there is a problem with dirt the gas sup ply or the thermocouple needs replacement Modifica...

Page 13: ...able fireguard conform ing to BS 8423 is used especially where young children pets the elderly or infirm are concerned The manufacturer of this appliance considers all surfaces as working surfaces with the exception of the control knob Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted...

Page 14: ...ack panel of the appliance The wall must be structurally sound and constructed from a material capable of withstanding moderate heat Finished plaster conventional wall paper and dry lined plasterboard are examples of suitable materials Materials such as flock blown vinyl and embossed paper which are sensitive to even small amounts of heat should be avoided as scorching and or dis colouration may o...

Page 15: ...for a few seconds Continue turning anti clockwise through the spark click to the PILOT light position ensuring the pilot has lit If not return the knob clock wise and repeat When the pilot lights after the spark keep the knob depressed for approximately ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ...

Page 16: ... the direction of the grain S SE ER RV VI IC CI IN NG G The appliance should be checked on an annual basis to ensure it is working safely and that there is no exces sive build up of soot The frequency of service will depend on usage but MUST be carried out at least once annually Servicing must be carried out by a competent person such as a CORGI registered installer Cleaning of the coals may be ca...

Reviews: