15
V
VEEN
NTTIILLA
ATTIIO
ON
N A
AN
ND
D R
RO
OO
OM
M SSIIZ
ZEE
Purpose provided ventilation of 100cm2 is required for this appliance. An openable window or equivalent is
also required.
Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2. Ventilation fitted under, or within
immediate vicinity of the appliance must not be used as it may adversely effect performance of the combus-
tion monitoring system (ODS) system.
The requirements of other appliances operating in the space or room must be taken into consideration when
assessing ventilation requirements, this will have been carried out by your CORGI registered installer.
A supply of fresh air into the room is advisable to maintain temperatures within limits.
The appliance MUST NOT be installed in a bedroom or bathroom.
For Republic of Ireland, see relevant rules in force.
The room size should be a minimum of 30m3 (1059ft3) to allow adequate circulation of air and ensure the cor-
rect operation of the fire. This volume may include adjacent spaces but these spaces must not be separated by
a door. In order to convert from cubic feet (ft3) to cubic metres (m3) divide the room volume (in ft3) by
35.3. This appliance is intended as a secondary source of heat only and should not be used in a room without
some form of background heating present.
O
OPPEER
RA
ATTIIN
NG
G IIN
NSSTTR
RU
UC
CTTIIO
ON
NSS
The pilot is visible behind the left hand side of the burner.
The control knob is located on the lower right hand side of the outer
case. It is of a spherical design and is marked as shown in the diagram
to the right;
Push in and turn the control knob to the SPARK position, and hold
there for a few seconds.
Continue turning anti-clockwise through the spark click to the PILOT
light position, ensuring the pilot has lit. If not, return the knob clock-
wise, and repeat.
When the pilot lights after the spark, keep the knob depressed for
approximately ten seconds. Now release the knob and the pilot
should stay alight. If the pilot is extinguished during use, wait three
minutes before repeating the ignition procedure. To achieve the
HIGH setting, push the control knob in slightly and continue turning
anti-clockwise to the high position. The main burner should light after a few seconds. To decrease the setting to
LOW, turn the control knob clockwise to the low setting.
To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot
position and release. To turn the fire OFF, keep the knob pressed in, return to the off position and release.
C
CO
OM
MB
BU
USSTTIIO
ON
N M
MO
ON
NIITTO
OR
RIIN
NG
G SSY
YSSTTEEM
M
This fire is fitted with a combustion monitoring safety device (ODS). If the appliance shuts down during use for
no apparent reason then several reasons may be suspected. If a door or window has been opened creating a
draught, then pilot disturbance could be the problem and removal of the draught should resolve this. The appli-
ance can then be re-lit in accordance with the previous section.
If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the appliance OFF,
call in your installer to check the appliance and ventilation. Remedial work must be carried out as required. DO
NOT allow the appliance to be used until the appliance and installation is passed as safe. If the pilot continues
to be extinguished, you must call your installer to check the operation of the complete appliance.
33..00
44..00
55..00
‘OFF’ position
‘SPARK’ position
‘LOW’ position
‘HIGH’ position
3