This appliance is a catalytic flueless flame effect gas fire, providing radiant and convected warmth. It is designed
to operate on Natural Gas following factory set adjustments, (see Data Plate on appliance for gas type and pres-
sure).
It is the LAW that all gas appliances and fittings are installed by a competent person (such as a CORGI registered
fitter) and in accordance with the Gas Safety (Installation and Use) Regulations 1998, the relevant British
Standards for Installation, Codes of Practice and the Manufacturers' Instructions. The installation shall also be
carried out in accordance with the following regulations:
The Building Regulations issued by the Department of the Environment, the Building Standards (Scotland)
(Consolidation) Regulations issued by the Scottish Development Department.
R
Reelleevvaanntt BBrriittiisshh ssttaannddaarrddss iinnssooffaarr aass tthhee rreelleevvaanntt aarreeaass aarree nnoott ccoovveerreedd bbyy tthheessee iinnssttrruuccttiioonnss..
N
Noottee:: FFoorr R
Reeppuubblliicc ooff IIrreellaanndd,, rreeffeerreennccee sshhoouulldd bbee m
maaddee ttoo tthhee rreelleevvaanntt ssttaannddaarrddss ggoovveerrnniinngg iinnssttaallllaattiioonn.. ((IISS
881133:: 11999966))
Failure to comply with these regulations could lead to prosecution and deem the warranty
invalid.
This appliance must be installed in accordance with the rules in force and used only in a suf-
ficiently ventilated space. A minimum of 100cm
2
(15.5 in
2
) purpose provided ventilation is
required for this appliance, an openable window or louvre is also required. To reduce the pos-
sibility of draughts entering the room via the air vent, we recommend the use of "Black Hole"
or "Vortex" type vents featuring internal baffles.
Consult ALL instructions before installation and use of this appliance.
This appliance is free from any asbestos material. Refractory panels are constructed from
ceramic fibre.
SSeeccttiioonn
C
Coonntteennttss
PPaaggee N
Noo..
11..00
IIm
mppoorrttaanntt N
Nootteess
11
22..00
A
Apppplliiaannccee D
Daattaa
22
33..00
IInnssttaallllaattiioonn R
Reeqquuiirreem
meennttss
22
3.1 Room Sizing
2
44..00
SSiittee R
Reeqquuiirreem
meennttss
22
4.1 Ventilation
3
55..00
U
Unnppaacckkiinngg tthhee A
Apppplliiaannccee
44
5.1 Component Checklist
4
66..00
G
Gaass SSuuppppllyy R
Roouutteess
44
77..00
PPrreeppaarriinngg tthhee A
Apppplliiaannccee
55
7.1 Fixing the Appliance
5
7.2 Checking the Burner
6
SSeeccttiioonn
C
Coonntteennttss
PPaaggee N
Noo..
88..00
TTeessttiinngg aanndd C
Coom
mm
miissssiioonniinngg
66
8.1
Operating the Appliance
6
8.2 Spark Failure
6
8.3 Setting pressure
6
8.4 Fitting the Frame Assembly
7
99..00
B
Brriieeffiinngg tthhee ccuussttoom
meerr
77
1100..00
SSeerrvviicciinngg
77
10.1 Servicing the Burner Tray
8
10.2 Pilot Assembly
8
10.3 Catalysts
8
10.4 Testing for Firebox Leakage
9
1111..00
TTrroouubblleesshhoooottiinngg G
Guuiiddee
1100
U
Usseerr IInnssttrruuccttiioonnss
11..00
3
4
4
4
4
5
6
6
6
7
7
8
8
8
8
8
9
9
9
10
10
10
11
12
13
1000mm
177mm
600mm