This appliance may be installed with or without a hearth. If a hearth is fitted, the size and design may be as
desired. If the appliance is to be sited near a disused natural draught flue it is recommended that the old flue
should be partially sealed off to prevent draughts, however some ventilation will be required to prevent con-
densation. The appliance is designed to be wall mounted. It is possible to install the appliance onto certain
types of combustible materials - see section entitled ‘Clearances to combustible materials’.
In the event that the fire is sited near a disused or unserviceable fireplace served by a natural draught flue, any
existing under grate draught device should be sealed off to prevent loss of heat or creation of draughts. The
passageway into the flue should be partially sealed to prevent excessive draughts, however some ventilation
will be required in the old flue to prevent condensation and dampness. Advice should be sought from your
local building control officer.
R
RO
OO
OM
M SSIIZ
ZIIN
NG
G
The room size should be a minimum of 30m
3
(e.g. 11’6” x 11’6” x 8’) to allow adequate circulation of air and
ensure the correct operation of the fire. This volume may include adjacent spaces but these spaces must not
be separated by a door. To calculate a room size in cubic metres (m
3
) divide the room volume in cubic feet
(ft
3
) by 35.3.
SSIITTEE R
REEQ
QU
UIIR
REEM
MEEN
NTTSS
TThhiiss aapppplliiaannccee iiss ddeessiiggnneedd ttoo bbee w
waallll-hhuunngg.. D
Doo nnoott rreecceessss aannyy ppaarrtt ooff tthhee aapppplliiaannccee iinnttoo tthhee w
waallll..
This Appliance may be installed in any room in a home, however there are exceptions, and the appliance may
not be used in the following rooms;
· Bedrooms - or areas which are mainly used for sleeping.
· Bathrooms - or areas where large amounts of steam are likely to be generated.
Installation in living rooms is common, however other rooms such as kitchens, dining rooms and hallways are
permitted, providing a suitable natural gas supply is available, and rooms sizing and ventilation requirements
are strictly adhered to (see section 4.1).
The appliance is designed to be versatile, and as such will operate correctly when exposed to normal gentle
draughts experienced within the home. It is not recommended, however that the appliance be installed in areas
where it is likely to be exposed to persistent strong draughts, that may be generated by outside doors or win-
dows, air vents etc. It is recommended that the appliance should not be installed within 500mm of any air vent.
A
APPPPLLIIA
AN
NC
CEE D
DA
ATTA
A
Gas Group
G20 Natural Gas CAT I2H
Inlet Pressure
20 mbar
Max Energy Input
Gross 2.6 kW
Net
2.35 kW
Max Gas Rate
0.25 m3/h
Min Energy Input
Gross 1.5 kW
Net
1.35 kW
Pilot Energy Input
Gross 166 W
Net
150 W
Burner Pressure High
13.5 mbar. (+/-0.75 mbar). Hot
13.0 mbar. (+/-0.75 mbar). Cold
Low
4.2 mbar. (+/-0.25 mbar). Hot
3.7mbar (+/-0.25 mbar). Cold
Main burner flow restrictor
Stereo 1.30mm (1/4” BSP)
Oxypilot
SIT/Bray 9082
Gas Inlet Connection
8mm inlet restrictor elbow
Ignition
Piezo spark
Spark Gap
4.0 mm (± 1.0mm)
Please see Data Badge affixed to appliance for current data.
This appliance is for use only with the gas type, and at the pressure stated on the appliance Data Badge.
22..00
33..00
33..11
44..00