9
FFIIN
NA
ALL FFIITTTTIIN
NG
G O
OFF TTH
HEE
FFR
RA
AM
MEE A
ASSSSEEM
MB
BLLY
Y
The facia panel is supported by four M6
screws which protrude from the front of the
outer casing. Ensure each screw is unscrewed
approximately one turn from the fully screwed
in position in order to create a 2mm gap
(shown). Simply hang the facia panel onto the
outer casing ensuring that the corresponding
keyhole shaped holes engage the screwheads
fully.
B
BR
RIIEEFFIIN
NG
G TTH
HEE C
CU
USSTTO
OM
MEER
R
All instructions must be handed to the user for
safekeeping. Show the customer how to light
and control the fire.
After commissioning the appliance, the cus-
tomer should be instructed on the safe use of
the appliance and the need for regular servic-
ing. Frequency of service depends on usage,
but MUST be carried out at least once annual-
ly.
Advise that cleaning of the fire maybe achieved when the fire is cold using a
damp cloth and mild detergent on most surfaces. Advise that the fire will emit a
"newness" smell for a time after initial commissioning and that extra ventilation
may be needed during this time.
Recommend that a guard be used for the protection of the young, pets, the eld-
erly and the infirm
SSEER
RV
VIIC
CIIN
NG
G
Isolate the fire from the gas supply. Ensure that the fire is fully cold before attempting service. A suggested pro-
cedure for servicing is detailed below.
1. Lay out the dustsheet and tools.
2. Remove the facia section. Removal is the reverse of fitting as detailed in section 8.4.
3. Remove the glass door assembly (4 screws) and clean carefully.
4. Inspect the burner and the catalysts and clean if necessary with a soft brush.
5. Disconnect the gas supply.
6. Undo the four screws retaining the burner support brackets to the base and rear of the firebox.
7. Remove the burner unit, strip off the burner pipes and clean thoroughly.
8. Clean the in-line restrictor, pilot assembly and the burner tube. Do not attempt to remove the pilot
injector as this can cause damage.
9. Re-assemble components.
10. Turn on the gas supply and leak test. Check pilot and burner for good ignition.
11. Refit the glass door assembly, ensuring a good seal.
12. Refit the facia as detailed in section 8.4.
13. Check the purpose provided ventilation is un-obstructed.
14. Light the fire and test setting pressures.
15. Check safe operation of the appliance.
For specific servicing instructions, see relevant sections.
99..00
1100..00
88..44
Decorative wings removed for clarity