OPERATION AND CONTROLS
It is most important that the operator of this gas appliance has fully read and understood all the operating,
cleaning and maintenance procedures as laid out in these instructions.
USER INSTRUCTIONS
9
POSITION 1
OFF
POSITION 2
IGNITION/PILOT
POSITION 3
MAXIMUM SETTING
POSITION 4
MINIMUM SETTING
Lighting Procedure
1. Push down the lever until the spark ignition begins to ‘click’ (position 2) and continue to hold down for 10 to 15
seconds until the pilot establishes.
2. With the pilot established, give the mechanism the extra 2-3mm downward push to allow gas to the main burner.
3. Slowly lift the lever to position 4 to give the minimum setting.
4. Slowly lift the lever again to position 3 to give the maximum setting.
5. When turning down to the minimum setting from maximum,
it is essential that the lever is fully pushed down
to the ignition setting and then lifted back up to the minimum setting.
6. To switch off the appliance completely, simply lift the lever fully to the top position.
Note:
The pilot assembly fitted to this appliance has an oxygen depletion sensor built in to monitor the room for
products of combustion. If the sensor should operate and switches the appliance off, re-ignite the appliance
following the procedure above. Should the appliance repeatedly activate the sensor, a specialist should be
called to inspect the appliance.
7. The fire must always be run on the high setting for at least the first 30 minutes to allow the chimney/flue to
warm. This allows the ‘pull’ of the flue to commence. After this period, a lower setting can be obtained by sliding
the knob down to POSITION 4.
In the event of failure of the normal means of ignition, push down the lever fully and light the pilot with a naked
flame from beneath the burner tray.
WARNINGS:
Never throw any type of rubbish on or otherwise disturb the fuel bed.
Any alteration to this appliance including its ceramic components may render it inoperable and unsafe.
ALWAYS run this appliance on the high setting for the first 30 minutes (minimum) - Failure to do this
may result in poor combustion and excessive sooting.
Fig. 8