background image

Catalogue number(s): 0 882 30

Technical data sheet: F01163EN/01  

Updated: 30/03/2015  

             Created: 07/07/2010

1/8

Configuration tool with screen

128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex

Tel: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88

www.legrand.com

Using this infrared configuration tool the user can, without touching the 

device:

-  set the parameters of SCS and KNX self-contained sensors, dynamic 

light strips and SARLAM bulkhead lights (time delay, daylight setpoint, 

detection sensitivity, etc.)

-   adjust, correct, debug the system according to the characteristics of the 

installation location and customer requirements

-  save the settings (maximum of up to 26 configuration files)

- duplicate onto other sensors (copy/paste a typical setting)

Infrared communication technology (4 m max.) 

In the direction of the product to be measured

At a maximum angle of +/-15° in the axis of the IR transmission and 

reception LED (see figure)

4 m

4 m

+/- 15°

+/- 15°

Backlit screen (automatic switch-off)

Weight: 71 g

Impact resistance: IK04

Operating temperature: -5°C to +45°C

Storage temperature: -20°C to +70°C

Recharging:  Use a mini USB cable (not supplied) to recharge the 

configuration tool via a standard USB socket.

Note:  Updating software is available on our website

Works with all factory pre-set compatible sensors (infrared, ultrasound 

or dual technology) with dynamic light strips and SARLAM bulkhead 

lights.

After fully interrogating the device, only the parameters concerning this 

device appear.

CONTENTS Page

1. 

Use

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

2. 

Technical characteristics

. . . . . . . . . . . . . . .1

3. 

Navigation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

4. 

Updating

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5. 

 

Standard EN12464-1  

recommendations

  . . . . . . . . . . . . . . . . . . . . .7

6. 

Care

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

7. 

Standards

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

2. TECHNICAL CHARACTERISTICS

2. TECHNICAL CHARACTERISTICS (CONTINUED)

1.USE

Display screen

Control and navigation 

keys

On/Off and OK

IR transmission 

and reception LED

Function access 

keys
Mini-USB 

connector

Summary of Contents for 0 882 30

Page 1: ...he product to be measured At a maximum angle of 15 in the axis of the IR transmission and reception LED see figure 4 m 4 m 15 15 Backlit screen automatic switch off Weight 71 g Impact resistance IK04 Operating temperature 5 C to 45 C Storage temperature 20 C to 70 C Recharging Use a mini USB cable not supplied to recharge the configuration tool via a standard USB socket Note Updating software is a...

Page 2: ... 2 3 s 1 2 3 5 4 6 Sensor parameter Advanced mode Files Sensor PnL Sensor parameters 1 1 2 3 Time delay 000 H 15 Min 00 Sec Max time delay 255 H 59 Min 59 Sec A Daylight setpoint 0500 lux Max 1275 lux C Sensitivity Very high US High HF High PIR Very high High Medium Low B Detection scheme E IR and US Maintain IR or US Retrigger IR or US Initial IR and US IR or US HF only PIR and HF PIR or HF IR on...

Page 3: ...oint Value at which the load switches on if the light level is less than the setting and goes off if it is above this setpoint The daylight setpoint can be set up to a maximum of 1275 lux D Mode There are 4 different operating modes Auto on Auto off mode Comes on automatically On detection of a presence if there is insufficient natural light Turns off automatically If no presence is detected and a...

Page 4: ...ode Files Sensor PnL Files 3 Files File name 3 NAVIGATION CONTINUED 3 NAVIGATION CONTINUED The Files menu can be used to display the customised settings saved Up to 26 files can be saved xx H xx MIN xx Sec PIR High US Low Closed loop xxx Lux x Lux Light regulation Mode Detection scheme Detection scheme Detection scheme Alert Time delay Sensitivity Sensitivity Loop type Daylight setpoint Provision ...

Page 5: ...uct documentation is displayed 5 Install the updating file 6 Click on Yes 8 Select the desired language then click OK 7 Click on Yes 9 Click on Next 3 Click on the icon to access software downloading 4 Download the file 3 2 7 Settings 4 1 Installing the software Files Sensor PnL Test Tool config Settings 6 Languages Version Battery A C B Version Firmware X X XX B Languages Français English Italian...

Page 6: ...lete 16 Click on Finish 1 Launch the application shortcut on the Desktop 15 Select Install this driver software anyway 11 Click on Browse to indicate the destination directory 12 Click on Next 13 To create a software icon on your desktop check the corresponding box then click on Next This window summarises the tasks selected earlier 14 Click on Install to confirm these actions or else on Previous ...

Page 7: ...st be switched off Note All technical information is available on Commercial premises office buildings Passage areas and corridors 100 lux Stairs 150 lux Canteens 200 lux First aid room 500 lux Warehouse 100 lux Offices 300 500 lux Conference rooms 500 lux Reception rooms 300 lux Technical drawing 750 lux Manufacturing areas Packaging rooms 300 lux Visual work during manufacturing 1000 lux Assembl...

Page 8: ...lowing products Hexane En 60669 1 Methylated spirit Soapy water Diluted ammonia Bleach diluted to 10 Window cleaning products WARNING Always test before using other special cleaning products Directive CE Product standard EN 60 669 2 1 Environmental standards European Directive 2002 96 EC WEEE Waste Electrical and Electronic Equipment European Directive 2002 95 EC RoHS Restriction of Hazardous Subs...

Reviews: