CONTENTS 

PAGE 

1. Description - Use ................................ 1 

2. Product range ..................................... 1 
3. Overall dimensions ............................. 1 
4. Preparation - Connection .................... 1 
5. General characteristics ....................... 4 
6. Conformities and approvals ................ 5 
7. Auxiliaries and accessories................. 6 
 

 

 

1. DESCRIPTION

1. DESCRIPTION

1. DESCRIPTION

1. DESCRIPTION    ---- USE

 USE

 USE

 USE    

STOP & GO motor driven unit is an automatic resetting device for 
MCB’s, RCBO’s (P+N or 2P) and RCCB’s (2P). 

STOP & GO automatic resetting main functions are: 
. In case of tripping due to earth leakage or short circuit, it detects 
the presence of an insulation fault in the system before to reset. 
. In case of transient fault, it automatically resets the electrical 
circuit. 
. In case of permanent fault, (earth leakage or short circuit), it keeps 
the circuit open and notifies the user by a visual signal and, if 
necessary, by an acoustic signal (by an integrated contact) 
. These functions allow the continuity of operation of the involved 
circuits. 
. Cat. n° 4 062 89 is fitted with a self-test function that allows to test 
automatically every 56 days (hour and day of test are 

programmable) that the associated residual current device operates 
properly.  

Technology :

Technology :

Technology :

Technology :    

. DC electric motor with permanent magnets 

2. PRODUCT RANGE

2. PRODUCT RANGE

2. PRODUCT RANGE

2. PRODUCT RANGE    

Cat. N°

Cat. N°

Cat. N°

Cat. N° 4

 4

 4

 4    062 88:

062 88:

062 88:

062 88:    

. It automatically resets the associated device (P+N or 2P) in case of 
tripping after a transient fault. 
. It checks the status of the installation before to reset. 
. It reports any permanent fault (earth leakage or short circuit). 
Cat. N°

Cat. N°

Cat. N°

Cat. N° 4

 4

 4

 4    062 89:

062 89:

062 89:

062 89:    

. In addition to the same functions as cat. n° 4062 88, it allows an 
automatic periodic test of the associated 30 mA residual current 
device. 

Width = 2 modules (35,4 mm) 

Rated Vol

Rated Vol

Rated Vol

Rated Voltage & Freq

tage & Freq

tage & Freq

tage & Frequency

uency

uency

uency::::    

. 230 V ~ 50 / 60 Hz with standard tolerances. 

Operating voltages:

Operating voltages:

Operating voltages:

Operating voltages:    

. Minimum (0,85 x Un) : 195,5 V 
. Maximum (1,1 x Un) : 253 V 
 

 

3. OVERALL DIMENSIONS

3. OVERALL DIMENSIONS

3. OVERALL DIMENSIONS

3. OVERALL DIMENSIONS    

4. PREPARATION

4. PREPARATION

4. PREPARATION

4. PREPARATION    ----    CONNECTION

CONNECTION

CONNECTION

CONNECTION    

Fixing:

Fixing:

Fixing:

Fixing:    

. On symmetric rail EN/IEC 60715 or DIN 35. 

Operating posi

Operating posi

Operating posi

Operating positions:

tions:

tions:

tions:    

. Vertical, Horizontal, backwards, on the side 
 

 
 

Supply:

Supply:

Supply:

Supply:    

. Supply Phase and Neutral from the top on the extractable connector 
. It is compulsory to connect Phase and Neutral downstream of the 
associated device and the protection conductor to the connector at the 
bottom of this device. Stop & Go will not work correctly if the protection 

conductor is not connected. 

List of possible associations

List of possible associations

List of possible associations

List of possible associations::::    

. 2P RCCBs 
. 2P RCBOs (2 poles protected or P+N, 1 pole protected) 
. 2P MCBs (2 poles protected or P+N, 1 pole protected) 

 

 

  Technical data sheet: F01284EN/00 

Updated: - 

Created: 11/11/2011 

 

Summary of Contents for 4 062 88

Page 1: ...lock for small or large model For locking the handle of the modular devices MCBs RCCBs RCBOs or isolating switches in OFF position Voltage surge protectors p 66 70 4 063 19 Keor UPS p 678 Pack Cat Nos Connected STOP GO remote control resetting For remotely switching via a smartphone or tablet 1 module per pole RCCBs and RCBOs up to 63 A Examples of use In the event of unwanted tripping generated b...

Page 2: ...liaries 71 5 8 8 17 7 61 83 44 77 7 84 5 DX3 remote control 74 3 17 7 35 4 61 83 44 80 5 98 8 DX3 Stop Go automatic resetting 74 3 35 4 61 83 44 80 5 113 7 Change over switches 68 17 7 35 6 60 83 44 74 94 CX3 latching relays 64 17 8 17 8 35 6 35 6 61 84 5 44 70 2 94 8 CX3 contactors up to 25A 66 3 61 17 8 17 8 35 6 35 6 61 84 5 44 72 6 67 3 94 8 CX3 contactors 40A 63A 62 35 6 53 4 53 4 60 83 44 68...

Page 3: ...t protect the installation against lightning strikes For an efficient protection against lightning use voltage surge protectors The Autotest version is specially suitable for installations equipped with residual current protection devices RCD s and RCBOs STOP GO periodically does an automatic test of the functionning of residual current protection devices The manual test is no longer needed Alarm ...

Page 4: ...ry handles SD 406260 Front external handle Cat No 4 063 19 20 Extension supplied with the external handle Cat No 4 063 19 20 Auxiliary contact 4P DX3 MCB Padlock Cat No 4 063 13 not supplied n Example of mounting on a DX3 MCB ...

Page 5: ...N Cat N 4 4 4 4 062 88 062 88 062 88 062 88 It automatically resets the associated device P N or 2P in case of tripping after a transient fault It checks the status of the installation before to reset It reports any permanent fault earth leakage or short circuit Cat N Cat N Cat N Cat N 4 4 4 4 062 89 062 89 062 89 062 89 In addition to the same functions as cat n 4062 88 it allows an automatic per...

Page 6: ...TION continued Stripping length recommended Stripping length recommended Stripping length recommended Stripping length recommended 7 mm Screw head Screw head Screw head Screw head Slotted diameter 3 5 mm Recommended tightening torque Recommended tightening torque Recommended tightening torque Recommended tightening torque 0 4 0 5 Nm Tools required Tools required Tools required Tools required For t...

Page 7: ...nt fault has disappeared the resetting of the Stop Go and of the associated device is carried out by the Stop Go handle isolating and power handles together Selector AUTO MAN Selector AUTO MAN Selector AUTO MAN Selector AUTO MAN The selector enables and disables the automatic remote control Positions AUTO possibility to automatically or manually control tripping and re setting MAN manual control o...

Page 8: ...c strength lectric strength lectric strength lectric strength 2500 V Mechanical endurance Mechanical endurance Mechanical endurance Mechanical endurance 20000 operations Electrical endurance Electrical endurance Electrical endurance Electrical endurance In accordance with the requirements of the standards of the associated protection device Enclosure material Enclosure material Enclosure material ...

Page 9: ... reset of MCB s RCBO s RCCB s for household and similar purposes Electromagnetic compatibility EN 61543 Legrand devices can be used under the conditions of use as defined by IEC EN 60947 7 7 7 7 AUXILIARIES AUXILIARIES AUXILIARIES AUXILIARIES AND ACCESSORIES AND ACCESSORIES AND ACCESSORIES AND ACCESSORIES Signal Signal Signal Signalling ling ling ling auxiliaries auxiliaries auxiliaries auxiliarie...

Page 10: ...7 mm 3 5 mm 0 5 Nm max Ø 4 mm 4 062 89 30 mA 16 A In 100 A 63 A DX3 10000 G O MAX 2 5 mm 2 2 x 1 5 mm2 Pz 1 17 5 mm 17 5 mm 2P Hpi ʌ 1P N 2P 63 A 2 8 Nm max 1P N N0265B LE04414AB 4 062 88 89 09 12 01 WP ...

Page 11: ...ición ON pasar el selector de la posición AUTO a la posición MAN y volver a pasarlo a la posición AUTO 2 El primer test automático de la función diferencial es instantáneo El siguiente test se realizará 56 días y 8 horas después de reali zarse el primero y permitirá decalar este test a las horas nocturnas los tests sucesivos se realizarán cada 56 días 8 semanas Programação 1 Após colocar sob tensã...

Page 12: ...3 Auto test 4062 88 89 4062 88 89 4062 88 89 4062 88 89 I 30 mA ...

Page 13: ...r rejimlerinde kullanilabilir CA SD Polish Rd0 rezystancja nie pozwalająca na załączenie wartość rezystancji pomiędzy przewodami czynnymi i uziemieniem 225kΩ Rd rezystancja pozwalająca na załączenie wartość rezystancji pomiędzy przewodami czynnymi i uziemieniem 375kΩ Rcc0 rezystancja nie pozwalająca na załączenie wartość rezystancji pomiędzy przewodami czynnymi 0 75Ω Rcc rezystancja pozwalająca na...

Reviews: