STOP & GO automatic resetting

STOP & GO automatic resetting

STOP & GO automatic resetting

STOP & GO automatic resetting

 

 

Cat. N°(s)

Cat. N°(s)

Cat. N°(s)

Cat. N°(s)    : 4

: 4

: 4

: 4    062 88 / 89

062 88 / 89

062 88 / 89

062 88 / 89 

 

 

4. 

4. 

4. 

4. PREPARATION

PREPARATION

PREPARATION

PREPARATION    ----    CONNECT

CONNECT

CONNECT

CONNECTION

ION

ION

ION

 (continued):

    

- In case of an unwanted tripping of the associated device and 

during the verification of the state of the electric circuit: 

The power handle is down. 
The isolating handle is up. 

 

- If the Stop & Go detects a permanent fault after a tripping, the 
isolating handle goes down 

 

- If the Stop & Go doesn’t detect a permanent fault, it returns to 
normal operation (reset of the associated device): both handle 
are upward. 

 

    

WARNING

WARNING

WARNING

WARNING    : : : : the stop & go makes only one attempt of resetting. 

Time of a re

Time of a re

Time of a re

Time of a re----setting

setting

setting

setting cycle

 cycle

 cycle

 cycle: : : :     

. <

. <

. <

. <    2 sec 

Tripping

Tripping

Tripping

Tripping by the test button of the 

 by the test button of the 

 by the test button of the 

 by the test button of the associated residual current

associated residual current

associated residual current

associated residual current    

device

device

device

device::::    

. In auto mode, when tripping the associated device by the test 
button, if the test button has been pushed more than 1 second, the 
Stop & Go unit will reset the associated device then switch it off 
again. It will be necessary to manually reset the Stop & Go. 

 

 

4. 

4. 

4. 

4. PREPARATION

PREPARATION

PREPARATION

PREPARATION    ----    CONNECTION

CONNECTION

CONNECTION

CONNECTION

 (continued):

    

Resetting by the Stop & Go handle

Resetting by the Stop & Go handle

Resetting by the Stop & Go handle

Resetting by the Stop & Go handle::::  

. When the permanent fault has disappeared, the resetting of the Stop 
& Go and of the associated device is carried out by the Stop & Go 
handle (isolating and power handles together) 

 

 

 

 

 

 

Selector AUTO / MAN:

Selector AUTO / MAN:

Selector AUTO / MAN:

Selector AUTO / MAN:    

. The selector enables and disables the automatic remote control. 
. Positions: 

- AUTO: possibility to automatically or manually control tripping and 
re-setting. 

- MAN: manual control only by the handle of the Stop & Go (isolating 
and power handles together) 

. Signalling by LED: 

- Green fixed: associated device “power on” and “Stop & Go” in AUTO 
mode. 
- Green flashing: “Stop & Go” in MAN mode. 

Signalling:

Signalling:

Signalling:

Signalling:    

. Signalling by LED: 

- Green fixed: associated device “power on” and “Stop & Go” in AUTO 
mode. Automatic resetting activated (and self-test activated for cat. n° 
4 062 89). 
- Green flashing: “Stop & Go” in MAN mode. 
- Red flashing: waiting for reset. 
- Red fixed: the device has tripped on fault (overload, short-circuit, 
residual current fault) or by control auxiliary. 
- Sliding front face downward: LED switched-off. 
- Yellow fixed (cat. n° 4 062 89 only): self-test function has detected a 
malfunction of the associated differential device. 

Self

Self

Self

Self----test programming

test programming

test programming

test programming ( ( ( (cat. n°

cat. n°

cat. n°

cat. n° 4

 4

 4

 4    062 89):

062 89):

062 89):

062 89): 

. After having connected cat. N° 4 068 89 to 
230 V ~ network, put the handle on ON 
position, switch the selector from “AUTO” 
position to “MAN” position then again to 
“AUTO” position. 
. The first automatic test of the residual 
current detection is carried out 
instantaneously. The next test will be 

carried out 56 days and 8 hours after the 
first test and this test will be shift during the 
night. Then the next test will occur every 56 
days (8 weeks).  

 

 

 

 

Technical data sheet: F01284EN/00 

Updated: - 

Created: 11/11/2011 

 

 

 

Isolating handle 

 

Power handle 

 

Isolating handle 

 

Power handle 

Isolating handle 

 

Power handle 

Isolating handle 

 

Power handle 

 

Summary of Contents for 4 062 88

Page 1: ...lock for small or large model For locking the handle of the modular devices MCBs RCCBs RCBOs or isolating switches in OFF position Voltage surge protectors p 66 70 4 063 19 Keor UPS p 678 Pack Cat Nos Connected STOP GO remote control resetting For remotely switching via a smartphone or tablet 1 module per pole RCCBs and RCBOs up to 63 A Examples of use In the event of unwanted tripping generated b...

Page 2: ...liaries 71 5 8 8 17 7 61 83 44 77 7 84 5 DX3 remote control 74 3 17 7 35 4 61 83 44 80 5 98 8 DX3 Stop Go automatic resetting 74 3 35 4 61 83 44 80 5 113 7 Change over switches 68 17 7 35 6 60 83 44 74 94 CX3 latching relays 64 17 8 17 8 35 6 35 6 61 84 5 44 70 2 94 8 CX3 contactors up to 25A 66 3 61 17 8 17 8 35 6 35 6 61 84 5 44 72 6 67 3 94 8 CX3 contactors 40A 63A 62 35 6 53 4 53 4 60 83 44 68...

Page 3: ...t protect the installation against lightning strikes For an efficient protection against lightning use voltage surge protectors The Autotest version is specially suitable for installations equipped with residual current protection devices RCD s and RCBOs STOP GO periodically does an automatic test of the functionning of residual current protection devices The manual test is no longer needed Alarm ...

Page 4: ...ry handles SD 406260 Front external handle Cat No 4 063 19 20 Extension supplied with the external handle Cat No 4 063 19 20 Auxiliary contact 4P DX3 MCB Padlock Cat No 4 063 13 not supplied n Example of mounting on a DX3 MCB ...

Page 5: ...N Cat N 4 4 4 4 062 88 062 88 062 88 062 88 It automatically resets the associated device P N or 2P in case of tripping after a transient fault It checks the status of the installation before to reset It reports any permanent fault earth leakage or short circuit Cat N Cat N Cat N Cat N 4 4 4 4 062 89 062 89 062 89 062 89 In addition to the same functions as cat n 4062 88 it allows an automatic per...

Page 6: ...TION continued Stripping length recommended Stripping length recommended Stripping length recommended Stripping length recommended 7 mm Screw head Screw head Screw head Screw head Slotted diameter 3 5 mm Recommended tightening torque Recommended tightening torque Recommended tightening torque Recommended tightening torque 0 4 0 5 Nm Tools required Tools required Tools required Tools required For t...

Page 7: ...nt fault has disappeared the resetting of the Stop Go and of the associated device is carried out by the Stop Go handle isolating and power handles together Selector AUTO MAN Selector AUTO MAN Selector AUTO MAN Selector AUTO MAN The selector enables and disables the automatic remote control Positions AUTO possibility to automatically or manually control tripping and re setting MAN manual control o...

Page 8: ...c strength lectric strength lectric strength lectric strength 2500 V Mechanical endurance Mechanical endurance Mechanical endurance Mechanical endurance 20000 operations Electrical endurance Electrical endurance Electrical endurance Electrical endurance In accordance with the requirements of the standards of the associated protection device Enclosure material Enclosure material Enclosure material ...

Page 9: ... reset of MCB s RCBO s RCCB s for household and similar purposes Electromagnetic compatibility EN 61543 Legrand devices can be used under the conditions of use as defined by IEC EN 60947 7 7 7 7 AUXILIARIES AUXILIARIES AUXILIARIES AUXILIARIES AND ACCESSORIES AND ACCESSORIES AND ACCESSORIES AND ACCESSORIES Signal Signal Signal Signalling ling ling ling auxiliaries auxiliaries auxiliaries auxiliarie...

Page 10: ...7 mm 3 5 mm 0 5 Nm max Ø 4 mm 4 062 89 30 mA 16 A In 100 A 63 A DX3 10000 G O MAX 2 5 mm 2 2 x 1 5 mm2 Pz 1 17 5 mm 17 5 mm 2P Hpi ʌ 1P N 2P 63 A 2 8 Nm max 1P N N0265B LE04414AB 4 062 88 89 09 12 01 WP ...

Page 11: ...ición ON pasar el selector de la posición AUTO a la posición MAN y volver a pasarlo a la posición AUTO 2 El primer test automático de la función diferencial es instantáneo El siguiente test se realizará 56 días y 8 horas después de reali zarse el primero y permitirá decalar este test a las horas nocturnas los tests sucesivos se realizarán cada 56 días 8 semanas Programação 1 Após colocar sob tensã...

Page 12: ...3 Auto test 4062 88 89 4062 88 89 4062 88 89 4062 88 89 I 30 mA ...

Page 13: ...r rejimlerinde kullanilabilir CA SD Polish Rd0 rezystancja nie pozwalająca na załączenie wartość rezystancji pomiędzy przewodami czynnymi i uziemieniem 225kΩ Rd rezystancja pozwalająca na załączenie wartość rezystancji pomiędzy przewodami czynnymi i uziemieniem 375kΩ Rcc0 rezystancja nie pozwalająca na załączenie wartość rezystancji pomiędzy przewodami czynnymi 0 75Ω Rcc rezystancja pozwalająca na...

Reviews: