CMS440N / CMS445N
Installation Instructions
4
8.
Attach face plate (not included) using one 6-32 x 1/2"
Phillips flat head screw (A) after the CMS440N has been
installed. (See Figure 5)
Figure 5
CMS445N
1.
Install a 15 Amp duplex outlet (not included) into the
electrical box.
2.
Loosen two Phillips head screws on the electrical box.
3.
Remove electrical box cover. (See Figure 6)
Figure 6
WARNING:
IMPROPER WIRING CAN LEAD TO DEATH
OR SEVERE PERSONAL INJURY! Grounding must be
installed by qualified personnel using a UL Recognized No.
12AWG Green grounding wire connected to grounding lug on
box.
WARNING:
ELECTRICAL SHOCK HAZARD! Turn off
power to device before performing service.
Figure 7
4.
Wire the CMS445N as required.
5.
Replace the electrical box cover. (See Figure 8)
6.
Tighten two Phillips head screws in electrical box cover.
Figure 8
8
(A) x 1
Face plate
(not included)
2
x 2
Electrical box
cover
3
Grounding Lug Location
Green Grounding
Wire
6
x 2
Electrical box
cover
5