OLCM1U
Installation Instructions
2
DISCLAIMER
Legrand
|
AV and its affiliated corporations and subsidiaries
(collectively “Legrand
|
AV”), intend to make this manual
accurate and complete. However, Legrand
|
AV makes no claim
that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Legrand
|
AV
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Legrand
|
AV
assumes no responsibility for accuracy, completeness or
sufficiency of the information contained in this document.
DEFINITIONS
MOUNTING SYSTEM:
A MOUNTING SYSTEM is the
primary Chief product to which an accessory and/or component
is attached.
ACCESSORY:
AN ACCESSORY is the secondary Chief
product which is attached to a primary Chief product, and may
have a component attached or setting on it.
COMPONENT:
A COMPONENT is an audiovisual item
designed to be attached or resting on an accessory or mounting
system such as a video camera, CPU, screen, display,
projector, etc.
WARNING:
A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION:
A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
IMPORTANT SAFETY INSTRUCTIONS
WARNING:
Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all mounting systems
are properly assembled and installed using the instructions
provided.
WARNING:
Failure to provide adequate structural strength
for this mounting system can result in serious personal injury
or damage to equipment! It is the installer’s responsibility to
make sure the structure to which this mounting system is
attached can support five times the combined weight of all
equipment. Reinforce the structure as required before
installing the mounting system.
WARNING:
Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components located within the mounting system of the
OLCM1U mounts does not exceed 250 lbs (113.4 kg).
NOTE:
"Moment" ratings have NOT been evaluated by UL.
WARNING:
Exceeding the maximum moment can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the mounting system
does not exceed a moment of 2000 ft-lbs. See table below for
specific column specifications.
WARNING:
Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING:
Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
WARNING:
Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING:
Use this mounting system with other outdoor
products only.
WARNING:
Always use two people or a mechanical lifting
device to safely lift and position equipment.
NOTE:
The OLCM1U flat panel floor/ceiling mounts are
intended to be used with UL Listed ODAC Series
columns (not included): ODAC0203, ODAC0304,
ODAC0405, ODAC0506, ODAC0708.
--SAVE THESE INSTRUCTIONS--
COLUMN
MODEL
Weight
capacity
Moment
Length (IN)
(ML)
Max
Design
Moment
(FT-LBS)
(MDM)
ODAC0203B
300 lbs (136 kg)
23 min - 36 max
2000
ODAC0304B
300 lbs (136 kg)
33 min - 48 max
2000
ODAC0405B
300 lbs (136 kg)
45 min - 60 max
2000
ODAC0506B
300 lbs (136 kg)
57 min - 72 max
2000
ODAC0708B
300 lbs (136 kg)
81 min - 96 max
2000