background image

 OLCM1U

Installation Instructions

2

DISCLAIMER

Legrand 

|

 AV and its affiliated corporations and subsidiaries 

(collectively “Legrand 

|

 AV”), intend to make this manual 

accurate and complete. However, Legrand 

|

 AV makes no claim 

that the information contained herein covers all details, 
conditions or variations, nor does it provide for every possible 
contingency in connection with the installation or use of this 
product. The information contained in this document is subject 
to change without notice or obligation of any kind. Legrand 

|

 AV 

makes no representation of warranty, expressed or implied, 
regarding the information contained herein. Legrand 

|

 AV 

assumes no responsibility for accuracy, completeness or 
sufficiency of the information contained in this document.

DEFINITIONS

MOUNTING SYSTEM: 

A MOUNTING SYSTEM is the 

primary Chief product to which an accessory and/or component 

is attached.

ACCESSORY: 

AN ACCESSORY is the secondary Chief 

product which is attached to a primary Chief product, and may 

have a component attached or setting on it.

COMPONENT: 

A COMPONENT is an audiovisual item 

designed to be attached or resting on an accessory or mounting 
system such as a video camera, CPU, screen, display, 

projector, etc.

WARNING:  

A WARNING alerts you to the possibility of 

serious injury or death if you do not follow the instructions.

CAUTION:  

A CAUTION alerts you to the possibility of 

damage or destruction of equipment if you do not follow the 
corresponding instructions.

 IMPORTANT SAFETY INSTRUCTIONS

WARNING:  

Failure to read, thoroughly understand, and 

follow all instructions can result in serious personal injury, 
damage to equipment, or voiding of factory warranty! It is the 
installer’s responsibility to make sure all mounting systems 
are properly assembled and installed using the instructions 
provided.

WARNING:  

Failure to provide adequate structural strength 

for this mounting system can result in serious personal injury 
or damage to equipment! It is the installer’s responsibility to 
make sure the structure to which this mounting system is 
attached can support five times the combined weight of all 
equipment. Reinforce the structure as required before 
installing the mounting system.

WARNING:  

Exceeding the weight capacity can result in 

serious personal injury or damage to equipment! It is the 

installer’s responsibility to make sure the combined weight of 
all components located within the mounting system of the 
OLCM1U mounts does not exceed 250 lbs (113.4 kg). 

NOTE:  

"Moment" ratings have NOT been evaluated by UL.

WARNING:  

Exceeding the maximum moment can result in 

serious personal injury or damage to equipment! It is the 
installer’s responsibility to make sure the mounting system 
does not exceed a moment of 2000 ft-lbs. See table below for 
specific column specifications.

WARNING:  

Never operate this mounting system if it is 

damaged. Return the mounting system to a service center for 
examination and repair.

WARNING:  

Use this mounting system only for its intended 

use as described in these instructions. Do not use 
attachments not recommended by the manufacturer.

WARNING:  

Never operate this mounting system if it is 

damaged. Return the mounting system to a service center for 
examination and repair.

WARNING:  

Use this mounting system with other outdoor 

products only.

WARNING:  

Always use two people or a mechanical lifting 

device to safely lift and position equipment.

NOTE:  

The OLCM1U flat panel floor/ceiling mounts are 

intended to be used with UL Listed ODAC Series 
columns (not included): ODAC0203, ODAC0304, 
ODAC0405, ODAC0506, ODAC0708.

--SAVE THESE INSTRUCTIONS--

COLUMN 
MODEL

Weight 
capacity

Moment 
Length (IN) 
(ML) 

Max 
Design 
Moment 
(FT-LBS) 
(MDM)

ODAC0203B

300 lbs (136 kg)

23 min - 36 max

2000

ODAC0304B

300 lbs (136 kg)

33 min - 48 max

2000

ODAC0405B

300 lbs (136 kg)

45 min - 60 max

2000

ODAC0506B

300 lbs (136 kg)

57 min - 72 max

2000

ODAC0708B

300 lbs (136 kg)

81 min - 96 max

2000

Summary of Contents for Chief OLCM1U

Page 1: ... S T R U C T I O N S Large Outdoor Floor Ceiling Mount Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description OLCM1U ...

Page 2: ...uate structural strength for this mounting system can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this mounting system is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the mounting system WARNING Exceeding the weight capacity can result ...

Page 3: ...Installation Instructions OLCM1U 3 DIMENSIONS DIMENSIONS INCHES MILLIMETERS 1 91 48 4 0 HOLE LOCKOUT 5 AND 15 HOLE LOCKOUT 5 AND 20 HOLE LOCKOUT 7 6 HOLE LOCKOUT 10 2 48 63 0 10 HOLE LOCKOUT ...

Page 4: ...have de bocas Chiave a punte aperte Steeksleutel Clé à fourche By Hand A mano Von Hand Com a mão A mano Met de hand À la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perforar ...

Page 5: ...m 750x 323x 250 750x 344x 500 Z 8 1 4 20 x 5 8 Y 2 5 16 x 5 8 5 16 P 1 5 16 18 x 2 L 2 Interface bracket K 1 Center wind shield W 4 3 8 N 1 J 2 Side wind shield 1 4 20 x 2 Q 1 1 4 20 1 4 20 x 1 1 4 AA 4 5 16 18 BB 6 5 16 CC 8 1 4 H 1 Mount assembly R 1 5 16 18 S 2 5 16 T 2 1 4 DD 1 5 32 U 2 3 8 16 x 4 1 4 V 2 3 8 16 M 1 10 24 x 1 2 Interface Lockout Bag 2 Qty per bag Box column Hardware Kit ...

Page 6: ... PINCH POINTS Do not place fingers between movable parts 1 Slide mount assembly H onto ODAC Series Floor Ceiling Column See Figure 1 or See Figure 2 2 Use two 3 8 16 x 4 1 4 hex head tapping bolts U four 3 8 washers W and 3 8 16 hex nuts V See Figure 1 or See Figure 2 Figure 1 Figure 2 3 Install 1 4 20 x 1 1 4 button head cap screw X into mount assembly H to prevent column from rattling See Figure...

Page 7: ...ld K to sides of mount assembly H See Figure 5 Figure 5 3 Loosely install two 1 4 20 x 5 8 button head cap screws Z and two 1 4 washers CC into two center holes on center wind shield K See Figure 6 Figure 6 4 Hang two side wind shields J onto screws loosely installed in Step 3 using teardrop holes in center slots See Figure 7 5 Slide wind shields J horizontally to desired mounting position See Fig...

Page 8: ... See Figure 11 NOTE The diamond shape hole in the bracket corresponds to the center of the mount Figure 11 WARNING IMPROPER INSTALLATION CAN LEAD TO DISPLAY FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT Using screws of improper size may damage your display Properly sized screws will easily and completely thread into display mounting holes If spacers are required be sure to use lon...

Page 9: ...orting both sides of display lower display onto ceiling mount hooking top of interface brackets onto front of ceiling mount See Figure 12 WARNING IMPROPER INSTALLATION CAN LEAD TO DISPLAY FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT The display MUST be centered on the ceiling mount 3 Raise the latch mechanism on both interface brackets to lock bracket in place See Figure 12 Figur...

Page 10: ...kets allow 7 6 to 20 tilt and can be locked at 7 6 5 0 5 10 15 and 20 tilt See Figure 15 Figure 15 4 If necessary loosen button head tilt friction bolt located on side of interface bracket See Figure 16 5 Adjust tilt as required See Figure 16 6 The tilt may be locked at 7 6 5 0 5 10 15 and 20 using one 1 4 20 x 2 Phillips head screw N one 1 4 20 lock nut Q and two 1 4 washers T per interface brack...

Page 11: ...s Q This is NOT optional Using Padlocks Security 1 Add padlock not included to each interface bracket to lock latch and to provide security for displays See Figure 18 Figure 18 Using Bolts Nuts NOTE This will keep latch from opening but does not provide additional security for the displays 1 Use 5 16 18 x 2 hex head carriage bolt P 5 16 18 hex nut R and two 5 16 washers S to lock each interface br...

Page 12: ... 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 OLCM1U Installation Instructions 8800 003020 Rev02 2019 Legrand AV www legrandav com 03 19 ...

Reviews: