TIL1X2PT / TIL1X3PT / TIL1X4PT / TILVABPT
Installation Instructions
6
IMPORTANT ! :
It is easier to install the vertical
connector kit BEFORE the mounts are attached to the
wall. However, it can also be installed after the mounts
are attached to the wall.
1.
Add the vertical connector (N) to the top or bottom of the
mount, and fasten with two 1/4-20 x 1/2" Phillips pan head
screws (M) per vertical connector. (See Figure 4)
2.
Connect another wall mount to the other end of the vertical
connector to lengthen the video wall.
Figure 4
NOTE:
When connecting a mount to the bottom of an
installed
mount, the lower mount may be hung by its open slot
on the partially installed Phillips head screw (M) before
tightening the connection. (See Figure 5)
NOTE:
When connecting a mount above an already installed
mount, the upper mount may be slid down and
attached to the connector in the top of the already
installed mount.
Figure 5
Installing First Mount
The TIL1X2PT / TIL1X3PT /TIL1X4PT (TVF Series) LED wall
mounts are designed to be mounted to:
•
a bare 8" concrete wall or 8"x8"x16" concrete block
wall; or
•
a 3/4" thickness plywood-backed, 2" x 4" wood studs
(16" on center minimum) wall with a maximum drywall
thickness of 5/8"; or
•
a 3/4" thickness plywood-backed, steel stud wall
covered with drywall having a maximum thickness of
5/8".
Table 1: Fastener Information
1.
Hold furthest left, top wall mount against wall ensuring that
mounting slot is lined up with center line marked on the wall
in
Determining Installation Site
section. Double-check
with a level. (See Figure 6)
2.
Mark mounting holes in two top mounting slots along the
horizontal line marked in Step 3. (See Figure 6)
NOTE:
The mounting holes are 17.22" apart on-center. (See
Figure 6)
Figure 6
3.
Drill two pilot holes (see Table 1 for size) at each location
marked in Step 2 (See Figure 6) and follow fastener
information (appropriate for wall type) located in Table 1.
1
(M) x 4
(N)
(M) x 2
Top
mount
Lower
mount
Hang open slot
both screws (M).
screw (M) and tighten
installed Phillips head
onto partially
(N)
WALL
TYPE
PILOT
HOLE
FASTENERS (see PARTS
drawing)
Drywall
attached to
plywood-
backed walls
/Steel studs
Drywall
attached to
plywood-
backed walls
/Wood studs
1/2"
7/32" x 3"
-
1/4-20 x 2-1/2" hex head lag (not
included)
- 1/4" washer (not included)
- 1/4-20 Toggler Snaptoggle BB
(not included)
- 5/16 x 2-1/2" flanged hex head
lag (
C
)
- 5/16" washer (
D
)
- Adjustment washer (
A
)
Concrete or
concrete
block
3/8" x 3"
- 5/16 x 2-1/2" flanged hex head
lag (
C
)
- 5/16" washer (
D
)
- Adjustment washer (
A
)
- Fischer Anchor UX10x60R
(B)
2
17.22 inches
3
Line showing
slots for top
mounts in LED
center of mounting
Summary of Contents for CHIEF PT Series
Page 16: ...Installation Instructions TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT 16 ...
Page 25: ...Installation Instructions TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT 25 ...
Page 26: ...TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT Installation Instructions 26 ...
Page 27: ...Installation Instructions TIL1X2PT TIL1X3PT TIL1X4PT TILVABPT 27 ...