background image

3

Tensioned Advantage

®

 Electrol

®

 Suggested Methods of Installation

3/8" Threaded Rod  
(Not Supplied)

Hanger Bracket

Electrical 
Junction Box

Motor 
End

Variable Position 
Mounting Bracket

Audience Side

6 7/16"

6 1/16"

7 3/4"

3/8" Threaded Rod 
(Not Included) 
Attached To 
Mounting Bracket

Self-Trimming 
Flange

Finished
Ceiling

7 3/4"

7 3/4"

6 1/16" 

6 3/8"

3 7/16" 

7 7/16" 

6 7/16" 

Method 1

Method 2

9 1/4"

Summary of Contents for Da-Lite Advantage Electrol

Page 1: ...INSTRUCTION BOOK FOR Tensioned Advantage Electrol ...

Page 2: ...pliance is used subsequently 11 The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire electric shock or injury to persons 12 Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can s...

Page 3: ...plied Hanger Bracket Electrical Junction Box Motor End Variable Position Mounting Bracket Audience Side 6 7 16 6 1 16 7 3 4 3 8 Threaded Rod Not Included Attached To Mounting Bracket Self Trimming Flange Finished Ceiling 7 3 4 7 3 4 6 1 16 6 3 8 3 7 16 7 7 16 6 7 16 Method 1 Method 2 9 1 4 ...

Page 4: ...of case for proper installation clearance 4 Remove any protective foam covering the outside of the case 1 2 and 5 16 Open Wrench or Socket Driver 1 8 Hex Key included 5 For shipping purposes foam is also inserted between the roller brackets and end caps Figure 1 Remove these foam blocks from the ends 6 Remove the hanger brackets from the top of the case using a 1 2 wrench Do not discard the hardwa...

Page 5: ...ert the motor end square shaft into the motor end bracket junction box end and secure with the cotter pin Figure 2 5 Moving to the pin end of the case slide the pin end bracket until the hole fits securely over the pin and secure with the cotter pin Tighten the 1 4 20 nuts on the pin end bracket securely Figure 2 6 Complete electrical hook up by snapping motor wire connector into case connector Fi...

Page 6: ...uty cycle of 1 min on 3 min off Rated torque of model DL45EQ 6 28 is 6 N m with a duty cycle of 1 min on 3 min off Motor is intended for use in Da Lite screens incorporating a 3 00 and 3 25 roller diameter 1 Make sure motor collar is on motor 2 Collars keyway must line up with the key on the motor 3 Secure motor drive wheel on output shaft of motor and insert retaining clip Screen And Roller Assem...

Page 7: ...uctor 20 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board UP STOP DOWN BUS COM 5V Power Input 120VAC 60Hz Green Ground Ground Must be Connected to Building Ground Black Hot White Common Power Wire Data Cable RJ 45 Jack RJ 22 Jack Connection to Wall Switch R...

Page 8: ...ck Orange Purple Brown 220V Wiring Diagram with Operation Limit Adjustment Wall Switch 3 conductor 20 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party cont...

Page 9: ... switch is for operation only and CANNOT be used to make limit switch adjustments Therefore it is advised to wire the limit adjustment switch or provide a 3 conductor connection that is accessible Power Input 220VAC 50Hz Green Yellow Ground Blue Hot Brown Common Power Wire Data Cable RJ 45 Jack Black Down White Common Red Up Red Black White Inputs Output Black Down White L Common Red Up Push Down ...

Page 10: ...n from the projector s 5 or 12 volt screen trigger output to the length required to reach the VPI NOTE When extending the low voltage connection from the projector s screen trigger output polarity does not matter The red and black wires from the VPI are interchangeable IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used There...

Page 11: ...ed 2 Use 3 conductor 20 24 gauge wire to extend the switch wire to the required length 12VDC OUT The SCB 100 supplies power to the optional NET 100 network adaptor If you are using the NET 100 adaptor connect the power wire from the NET 100 to the 12VDC output terminal RS 232 COMMUNICATIONS The command protocols are as follows Screen 1 up 1U Screen 1 stop 1S Screen 1 down 1D Screen 2 up 2U Screen ...

Page 12: ...turn to run mode and no changes will be saved If this occurs return to step 3 for down limit adjustment or step 4 for up limit adjustment NOTE All screens except Parallax standard with 12 black drop at the top Screens with Parallax surface standard with 2 of black drop at the top 4 To adjust the up limit switch press and hold the up tactile button until the LED on the back of the switch turns soli...

Page 13: ...ut one foot and adjust the limit switch again Repeat until the desired position is set To Increase Screen Drop Turn the down limit switch screw counterclockwise to increase the amount of screen drop Run the screen down to test the stop position If the screen does not drop enough raise the screen about one foot and adjust the limit switch again Repeat until the desired position is set Do not adjust...

Page 14: ...ure across the common up and down wires will be a stop command Operation of Screen Operation Limit Adjustment Wall Switch 1 Press DOWN button on screen switch and screen will deploy out of case in downward direction 2 Press STOP button on screen switch and screen will stop if in movement 3 Press UP button on screen switch and screen will retract upward into case Up Button Stop Button Down Button U...

Page 15: ...ire in the down or up position Check for continuity Cut off old splice and reconnect Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Capacitor burned out Replace motor assembly Screen does not stop at correct position Limit switch out of adjustment See Screen Adjustment section Noise NOTE Screen will operate with a low pitched hum Squeaking rubber e...

Page 16: ...ourself against damage or loss in transit insure the product and prepay all transportation expenses TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited...